My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1987 - 1995
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MORELAND
>
7700
>
2300 - Underground Storage Tank Program
>
PR0231819
>
COMPLIANCE INFO_1987 - 1995
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2020 5:27:18 PM
Creation date
2/12/2020 2:26:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987 - 1995
RECORD_ID
PR0231819
PE
2351
FACILITY_ID
FA0003732
FACILITY_NAME
99 SHELL*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
01
SITE_LOCATION
7700 MORELAND ST
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
83
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> HUNTER ENVIRONMENTAL SERVICES, INC. FiNAL TEST RESULTS <br /> 18350 MT. LANGLEY STREET, SUITE 101 TEST DATE: 10-2-87 <br /> FOUNTAIN VALLEY, CA 92708 <br /> 800-247-9014 800-247-2186 <br /> CUSTOMER: SHELL LOCATION/IDENTIFICATION NO.: 204 752 441 <br /> ADDRESS: 7700 Moreland Court <br /> Stockton, CA <br /> TEST RESULTS SUMMARY <br /> LEAK LOKATOR RESULTS <br /> SYSTEM TANK SIZE WATER LEVEL ALR <br /> NO. PRODUCT GALLONS DIA/MATL INCHES INCHES GPH CONCLUSION RECOMMENDATIONS <br /> 1 Reg 8000 9511/ST 1/4 149 +.033 Tight <br /> PRODUCT LiNES - HYDROSTATIC PRESSURE TEST RESULTS <br /> SYSTEM TYPE OF PUMP POUNDS POUNDS MINUTES PRODUCT PRODUCT CONCLUSION <br /> NO. PRODUCT REMOTE SUCTION APPLIED HELD HELD LOSS CC's LOSS GPH /RESULT <br /> i Reg Red Jacket R/P 15 15 Tight <br /> NOTE: On suction systems, NEVER put more than 15 psi on any pump system. <br /> DETAIL OF TEST RESULTS <br /> TEST TIME LEAK RATE TEMPERATURE ABSOLUTE CHECK <br /> SYSTEM TEST LEVEL CLOCK DURATION COMPENSATION LEAK RATE TEST <br /> NO. PRODUCT NO. (IN.) STATE (HR-MiN) CC/DiV CC/MiN DELTA of CC/MIN CC/MIN GPH Y/N <br /> 1 Reg 1 149 11:00 60 Min 2.777 +9.413 +.023 +7.312 +2.100 +.033 <br /> *LEVEL - Inches from Tank Bottom to Test Level <br /> ALR - Absolute Leak Rate (Measured Leak Rate - Temperature Compensation) in Gallons Per Hour <br /> CONCLUSION - NFPA 329 criterion of +/- 0.05 GPA is used to certify tightness <br /> CERTIFICATION <br /> This is to certify that the above tank systems were tested, using the HUNTER ENVIRONMENTAL SERVICES, INC. LEAK <br /> LOKATOR according to all standard operating procedures. Those indicated as tight at full system meet the criterion <br /> established by the National Fire Protection Association Pamphlet 329 for Precision Testing. <br /> Tests Conducted and Certified By: Test Van No. 20 <br /> Team Manager: M. Ehlert <br /> Tank Testing Specialist: R. Chaverri <br />
The URL can be used to link to this page
Your browser does not support the video tag.