My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1987 - 1995
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MORELAND
>
7700
>
2300 - Underground Storage Tank Program
>
PR0231819
>
COMPLIANCE INFO_1987 - 1995
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2020 5:27:18 PM
Creation date
2/12/2020 2:26:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987 - 1995
RECORD_ID
PR0231819
PE
2351
FACILITY_ID
FA0003732
FACILITY_NAME
99 SHELL*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
01
SITE_LOCATION
7700 MORELAND ST
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
83
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM TANK SIZE WATER LEAK LOKATOR RESULTS* CONCL.COC <br /> PRODUCT GALLONS DIA/MA' NCHES LEVEL ALR co NC LUSIO <br /> INCHES GPH �OMMEN DATIONS TEST TANK <br /> OTHER INFORMATION <br /> PRODUCT LINES— HYDROSTATIC PRESSURE TEST RESULTS <br /> SYSTEM TYPE OF PUMP PRODUCT PRODUCT CONCLUSI <br /> # MINUTES LOSS LOSS <br /> NO. PRODUCT REMOTE SUCTION APPLIED APPLIED CC'S GPH RESUL- <br /> NOTE: On suction systems, NEVER put more than 15 psi on any pump system. <br /> OTHER CONTRACTORS,OFFICIALS, CUSTOMER REPRESENTATIVES PRESENT <br /> DETAIL OF TEST RESULTS <br /> TEST TIME LEAK RATE TEMPERATURE ABSOLUTE <br /> Y EM TEST LEVEL COMPENSATION LEAK RATE <br /> NO. NO. CLOCK DURATION <br /> (INCHES) START HRS.-MIN. CC/DIV CC/MIN of CC/MIN CC/MIN GPH <br /> /i <br /> I <br /> I <br /> LEVEL— INCHES FROM TANK BOTTOM TO TEST LEVEL <br /> ALR— ABSOLUTE LEAK RATE (MEASURED LEAK RATE—TEMPERATURE COMPENSATION) IN GALLONS PER HOUR <br /> CONCLUSION—NFPA 329 CRITERION OF ±0.05 GPH IS USED TO CERTIFY TIGHTNESS <br /> CERTIFICATION This is to certify that the above described tank systems were tested, using the HUNTER ENVIRONMENTAL <br /> SERVICES, INC. LEAK LOKATOR according to all standard operating procedures. Those indicated as tight at full <br /> system meet the criterion established by the National Fire Protection Association Pamphlet 329 for Precision Testin <br /> TESTS CONDUCTED BY CERTIFIED BY <br /> TEST VAN NO. TANK TESTING SPECIALIST SIGNATURE 1 I 1 11 DATE <br /> '" <br /> TANK TESTING SPECIALIST NAME TITLE <br />