My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1987 - 1995
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MORELAND
>
7700
>
2300 - Underground Storage Tank Program
>
PR0231819
>
COMPLIANCE INFO_1987 - 1995
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2020 5:27:18 PM
Creation date
2/12/2020 2:26:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987 - 1995
RECORD_ID
PR0231819
PE
2351
FACILITY_ID
FA0003732
FACILITY_NAME
99 SHELL*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
01
SITE_LOCATION
7700 MORELAND ST
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
83
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HUNT-JR ENVIRONMENTAL SERVICES, INC. FINAL TEST RESULTS <br /> 11350 MT. LANGLEY STREET, SUITE 101 O TEST DATE: 9-8-87 <br /> FOUNTAIN VALLEY, CA 92708 �. <br /> 800=247-9014 800-247-2186 f cv <br /> Ep�TH <br /> ENv�ROMI/SER COCATION/IDENTIFICATION NO.: 204-752-441 <br /> CUSTOMER: SHELL ER <br /> ADDRESS: 7700 Moreland Court <br /> Stockton, CA <br /> TEST RESULTS SUMMARY <br /> LEAK LOKATOR RESULTS <br /> SYSTEM TANK SIZE WATER LEVEL ALR <br /> NO. PRODUCT GALLONS DIA/MATL INCHES INCHES GPH CONCLUSION RECOMMENDATIONS <br /> 1 Regular 11 8000 9511/ST 0 146 -2.08 Leak <br /> 02 120 + .030 Tight <br /> PRODUCT LINES - HYDROSTATIC PRESSURE TEST RESULTS <br /> SYSTEM TYPE OF PUMP POUNDS POUNDS MINUTES PRODUCT PRODUCT CONCLUSION <br /> NO. PRODUCT REMOTE SUCTION APPLIED HELD HELD LOSS CC's LOSS GPH /RESULT <br /> 1 Regular Red Jacket 50 10 Pass <br /> NOTE: On suction systems, NEVER put more than 15 psi on any pump system. <br /> DETAIL OF TEST RESULTS <br /> TEST TIME LEAK RATE TEMPERATURE ABSOLUTE CHECK <br /> SYSTEM TEST LEVEL CLOCK DURATION COMPENSATION LEAK RATE TEST <br /> NO. PRODUCT NO. (IN.) STATE (HR-MIN) CC/DIV CC/MIN DELTA of CC/MIN CC/MIN GPH Y/N <br /> 1 Regular 1 146 3:03 12 Min 1.66 -125.53 +.017 +6.10 X131.63 -2.08 N <br /> 2 120 3:51 �9 Min,, 4.06 + 6.09 +.013 +4.19 + 1.90 +.030 N <br /> *LEVEL - Inches from Tank Bottom to Test Level <br /> ALR - Absolute Leak Rate (Measured Leak Rate - Temperature Compensation) in Gallons Per Hour <br /> CONCLUSION - NFPA 329 criterion of +/- 0.05 GPA is used to certify tightness <br /> CERTIFICATION <br /> This is to certify that the above tank systems were tested, using the HUNTER ENVIRONMENTAL SERVICES, INC. LEAK <br /> LOKATOR according to all standard operating procedures. Those indicated as tight at full system meet the criterion <br /> established by the National Fire Protection Association Pamphlet 329 for Precision Testing. <br /> Tests Conducted and Certified By: Test Van No. 30 <br /> Team Manager: Rudy Roessler <br /> Tank Testing Specialist: Roger Renko <br />