My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1987 - 1995
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MORELAND
>
7700
>
2300 - Underground Storage Tank Program
>
PR0231819
>
COMPLIANCE INFO_1987 - 1995
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2020 5:27:18 PM
Creation date
2/12/2020 2:26:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987 - 1995
RECORD_ID
PR0231819
PE
2351
FACILITY_ID
FA0003732
FACILITY_NAME
99 SHELL*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
01
SITE_LOCATION
7700 MORELAND ST
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
83
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. ur4[;-R E:JV,.IRONMENTAL SERVICES, INC. r2NAL TEST RESULTS <br /> 15405 REDHILL AVENUE, SUITE C TEST DATE: 3-11-87 <br /> TUSTIN, CALIFORNIA 92680 <br /> • 800-247-9014 600-247-2186 <br /> CUSTOMER: Shell LOCATION/IDENTIFICATION NUMBER: 204-7524-4107 <br /> ADDRESS: 7700 Moreland Court <br /> Stockton, CA <br /> TEST RESULTS SUMMARY <br /> Leal; Lokator Results* <br /> System Tank Size Water Level ALR <br /> No. Product Gallons Dia/Matl Inches Inches GPH Conclusion Recommendations <br /> 1 Super 8000 95 0 152 -.006 Tight <br /> 2 U/L 8000 95 0 155 +.002 Tight <br /> 3 R/L 8000 95 0 125 +.015 Tight Meets NFPA 329 criterion <br /> of 0.05 GPH accuracy; <br /> however, not all piping <br /> was included in test as <br /> required by NFPA 329. <br /> Other Information: Could not test R/L full system due to visual leak in vent line just below <br /> concrete coupling. <br /> PRODUCT LINES - HYDROSTATIC PRESSURE TEST RESULTS <br /> System Type of Pump Pounds Pounds Minutes Product Product Conclusion <br /> No. Product Remote Suction Applied Held Held Loss CC's Loss GPH /Result <br /> 1 Super Red Jacket 50 50 10 Tight <br /> 2 U%L Red Jacket 50 49 10 Tight <br /> 3 R/L Red Jacket 50 50 10 Tight <br /> Note: On suction systems, NEVER put more than 15 psi on any pump system. <br /> DETAIL OF TEST RESULTS <br /> Test Time Leak Rate Temperature Absolute Check <br /> System Test Level Clock Duration Compensation Leak Rate Test <br /> No. Product No. ( In. ) Start (Hr-Min) CC/DIV CC/MIN Delta -F CC/MIN CC/MIN GPH Y/N <br /> 1 Super 1 152 10:00 0-34 +7.929 +6. 431 + .020 +6.863 - .432 -.006 No <br /> 2 U/L 1 155 11:00 0-33 +2.625 +2.516 + .007 +2.331 + . 184 +.002 No <br /> 3 R/L 1 125 12:30 0-34 +5.084 +2,341 + .004 +1.332 +1.008 +,015 No <br /> *Level - Inches from Tank Bottom to Test Level <br /> ALR - Absolute Leak Rate (Measured LEak Pate - Terperature Compensation) in Gallons Per Hour <br /> Conclusion - NFPA 329 criterion of + 0.05 GPH is used to certify tightness <br /> CERTIFICATION <br /> This is to certify that the above tank systems were tested, using the HUNTER ENVIROMENTAL <br /> SERVICES, INC. LEAN; LOKATOR according to all standard operating procedures. Those indicated <br /> as tight at full system meet the criterion established by the National Fire Protection <br /> Association Pamphlet 329 for Precision Testing. <br /> Tests Conducted By: Test Van No. LL-21 <br /> Tank Testing ecialist: R. Chaverri <br /> Team Manage Pat Wheeler <br /> Certified By: y Y 17 <br /> Mi ael L. Ane etti , Field Supervisor Date <br />
The URL can be used to link to this page
Your browser does not support the video tag.