My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MORELAND
>
7700
>
2300 - Underground Storage Tank Program
>
PR0231819
>
INSTALL_2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2020 11:32:18 PM
Creation date
2/12/2020 4:19:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2005
RECORD_ID
PR0231819
PE
2351
FACILITY_ID
FA0003732
FACILITY_NAME
99 SHELL*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
01
SITE_LOCATION
7700 MORELAND ST
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
121
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Secondary' Containment <br /> Vacuum Sensing System <br /> Maximize protection with a vacuum <br /> _ a <br /> monitored secondary containment <br /> system . aw <br /> A Secondary Containment Vacuum Featunesand Benefits Facilitates periodic opetabilitytesting <br /> Sensing System for use with Veeder- Satis y Re uirements Leverage Existing Veeder-Root Systems <br /> to meet California's requuernent for <br /> Root's ATG Systems. The Secondary Uses STP asthevacutunsotureandworkswith <br /> Containment Vacuum Sensing (SCVS) �Z � Red jacket� <br /> sewndary space fortanksandlines JFESM <br /> as required by <br /> System is designed to detect leaks in double- . Satisfies the requ rernmts for(Lass I Leak Irt wm the SIP sump and c°nnects to the <br /> consoll e via intrinsically safe s`'iring <br /> walled tanks and piping systems while Detection as defined by the European . Able to share wiring conduit with other <br /> helping to contain a release of product while Standard EN 13160-2 Veciliff-Root intrinsically safe(LS)probes and <br /> 3rd Party,National Work Group and LGI 13 <br /> under vacuum.The system consists of: listed sensors including sump or line leak sensors. <br /> • interfaces to the Smart Serwr Interface with <br /> Reduce Exposure to Risk <br /> • Vacuum Sensors,connected to tank, Embedded Pressure Modem <br /> Alarms when vacuum cm-tot be maintained • Provides for positive shut down of pressurized <br /> sump or piping interstices or when replenish rate exceeds 85 liters per hour. lines when mquired. <br /> • A Submersible Turbine Pump(STP), . The Sys=alarms when liquid is detected in . Simple installation,no creed to mess with brine <br /> to provide a source of vacuum the secondary space <br /> • A Smart Sensor Interface with Embedded <br /> Pressure Module in a TLS-350 Operating Temperature Rating: Console Capability <br /> Monitoring System -25 degrees C to+70 degrees C The Vacuum Sensor is compatible with <br /> the following consoles: <br /> The Vacuum Sensor is interfaced to Veeder- Cable Length: Console <br /> 8 feet TLS-350R/EMC w/BIR" <br /> Root's TLS-350 Monitoring System via TLS-350 Plus/EMC Enhanced <br /> intrinsically safe wiring to provide system Sensor Dimensions: TLS-350/EMC <br /> status,replenish rate,alarm,and diagnostic 5'high x 5"wide 2"deep Upgrade Note:The Vacuum Sensor System requires <br /> the console to have version 24C software(or greater) <br /> information. along with an ECPU2 or ECPU w/NVMEM 1 board. <br /> Standard Models <br /> Vacuum Sensor Kits are available in a variety Veeder-Root P/N Description <br /> of models: 330020-467 4 Vacuum Sensor Kit'for steel tank <br /> 330020-468,-469,-470,-471 4 Vacuum Sensor Kit"for fiberglass tanks(4',6',8',10) <br /> 330020-486 4 Vacuum Sensor Kit"for no tank <br /> • For monitoring double-walled piping 330020-472 3 Vacuum Sensor Kit'for steel tank <br /> and sump interstices 33002G-473,-474,-476.-476 3 Vacuum Sensor Kit'for fiberglass tanks(4',6',8',10) <br /> • For monitoring double-walled steel tank 330020-485 3 Vacuum Sensor Kit"for no tank <br /> interstices(see back page) 330020-479 2 Vacuum Sensor Kit*for steel tank <br /> For double-walled fiberglass tanks 330020-481,-482,-483,-484 2 Vacuum Sensor Kit"for fiberglass tanks(4',6',8',10') <br /> • g 330020-480 2 Vacuum Sensor Kit'for no tank <br /> 857280-100 Vacuum Sensor for piping&sumps <br /> These kits differ in the number of vacuum 857280-200 Vacuum Sensor for steel tanks <br /> sensors and the configuration of associated 857280-301,-302,-303,-304 Vacuum Sensor for fiberglass tanks(4',6',8',10') <br /> liquid sensors.An inline kit mounted liquid 330020-448 Mounting Kit <br /> 332217-001 Relief Valve Assembly <br /> sensor is used for Vacuum Sensors 332250-001 Smart Sensor w/Embedded Pressure Sensor Module(7 Channel)" <br /> monitoring piping and sumps. An external Accessories Part Description Quanthy/Length Part Number <br /> liquid sensor(to be installed in the secondary 1/4"NPT Barbed Fittings 3 330020-487 <br /> space at the bottom of the tank) is provided 1/4"NPT Barbed Fittings 15 _330020-488 <br /> with one of the Vacuum Sensors in the steel 1/4"NPT Barbed Fittings 25 330020-489 <br /> and fiberglass tank kits to monitor the tank. Barbed Tee 1 576008-657 <br /> Vacuum Hose 25' 25' 332310-001 <br /> Vacuum Hose 50' 50' 332310-002 <br /> Vacuum Hose 100' 100' 332310-003 <br /> 3-Way Ball Valve 1 576008-649 <br /> Kits include mounting bracket,6'of vacuum hose,relief valve assembly to required)and the appropriate number of liquid sensors, <br /> 3-way ball valves, barbed fittings and hose clamps so that each vacuum sensor can monitor a single tank,sump or piping interstices. <br /> The Vacuum Sensing System requires one 7 channel Smart Sensor Interface with Embedded Pressure Module,8 channel Smar <br /> Sensor Modules(p/n 329356-004)can be used for vacuum Sensors eight and above. <br /> For more information call: 1-888-561-7942 <br /> �� VEEDER-ROOT <br />
The URL can be used to link to this page
Your browser does not support the video tag.