Laserfiche WebLink
NIFIED PROGRAM CONSOLIDATED FOF, <br /> TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br /> VI.PIPING CONSTRUCTION(Check all that apply) <br /> UNDERGROUND PIPING F ABOVEGROUND PIPING <br /> SYSTEM TYPE X 1. PRESSURE r 2. SUCTION F 3. GRAVITY F 1. PRESSURE I 2. SUCTION r 3. GRAVITY 459 <br /> CONSTRUCTION F 1. SINGLE WALL r 3. LINED TRENCH r 99. OTHER r 1. SINGLE WALL r 95. UNKNOWN 462 <br /> / X 2. DOUBLE WALL I 95. UNKNOWN r 2. DOUBLE WALL r 99. OTHER <br /> MANUFACTURE <br /> R MANUFACTURER 461 MANUFACTURER 463 <br /> F 1.BARE STEEL r 6. FRP COMPATIBLE Al 100%METHANOL r 1. BARE STEEL r 6. FRP COMPATIBLE Al 100%METHANOL <br /> MATERIALS AND r 2. STAINLESS STEEL r 7. GALVANIZED STEEL r 2. STAINLESS STEEL r 7. GALVANIZED STEEL <br /> CORROSION r <br /> PROTECTION 3. PLASTIC COMPATIBLE WITH CONTENTS r 95. UNKNOWN r 3. PLASTIC COMPATIBLE WITH CONTENTS r 8. FLEXIBLE(HDPE) r 99. OTHER <br /> X 4. FIBERGLASS I'B. FLEXIBLE(HDPE) r 99. OTHER F 4. FIBERGLASS F 9. CATHODIC PROTECTION <br /> r 5. STEEL W/COATING r 9. CATHODIC PROTECTION 464 r 5. STEEL W/COATING r 95. UNKNOWN 465 <br /> VII.PIPING LEAK DETECTION(Check all that apply)(A description of the monitoring program shall be submitted to the local agency.) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> I 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR r 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR LEAK, <br /> LEAK SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL SYSTEM FAILURE;ANDSYSTEM DISCONNECTION+AUDIBLE AND VISUAL ALARMS <br /> ALARMS r 2. MONTHLY 0.2 GPH TEST <br /> r 2. MONTHLY 0.2 GPH TEST r 3. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> F 3. ANNUAL INTEGRITY TEST(0.1 GPH) r 4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS: CONVENTIONAL SUCTION SYSTEMS(Check all that apply): <br /> r 5. DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING INTEGRITY r 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(0.1,GPH) r 6. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> F 7. SELF MONITORING F 7. SELF MONITORING <br /> GRAVITY FLOW: GRAVITY FLOW(Check all that apply): <br /> r 9. BIENNIAL INTEGRITY TEST(0.1 GPH) r 8. DAILY VISUAL MONITORING <br /> I 9. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND check one <br /> (Check one) ( ) <br /> X a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS r a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> I b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM I b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> DISCONNECTION <br /> r c. NO AUTO PUMP SHUT OFF IF c. NO AUTO PUMP SHUT OFF <br /> X 11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR r 11. AUTOMATIC LEAK DETECTOR <br /> RESTRICTION <br /> F 12. ANNUAL INTEGRITY TEST(0.1 GPH) r 12. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM: SUCTION/GRAVITY SYSTEM: <br /> r 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS r 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> r 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND IF 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND VISUAL <br /> VISUAL ALARMS ALARMS <br /> r 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW SHUT OFF OR r 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> RESTRICTION <br /> I 16. ANNUAL INTEGRITY TEST(0.1 GPH) I 16. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> F 17. DAILY VISUAL CHECK I 17. DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT IF 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE r 4. DAILY VISUAL CHECK <br /> DATE INSTALLED 468 r 2. CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS r 5. TRENCH LINER/MONITORING <br /> 1989 X 3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+AUDIBLE AND VISUAL ALARMS F 6. NONE 469 <br /> IX QWNFR/OPFRATQR RIG NAT[IRF <br /> I certify that the information provided herein is true and accurate to the best of my knowledge <br /> SIGNATURE FWNER/OP TOR DATE 470 <br /> 12/6/01 <br /> NAME OF OWNER/OPERATOR(print) 471 TITLE OF OWNER/OPERATOR 472 <br /> Bruce T. Marubashi for Equilon Enterprises LLC PERMIT ANALYST 925-766-3498 <br /> Permit Number(For local use only) 473 Permit Approved(For local use only) 474 I Permit Expiration Date(For local use only) 475 <br /> 6 <br />