Laserfiche WebLink
Stantec <br /> Report of Findings for the Waterfront Towers Separate Phase Hydrocarbon Investigation <br /> and Unocal Extraction Well Pilot Study <br /> Waterfront Towers Parking Lot <br /> March 4, 2011 <br /> drawdown of any significance was not observed in either well during the test. At 12:30 pm on <br /> November 16, 2010, pumping was initiated in GWE-2 while GWE-1 was still operating. <br /> On November 16, 2010 at 11:35 am, following 2.75 hours of GWE to 957 gallons total <br /> production, the submersible pump was shut down for adjustments due to diminished <br /> groundwater yield and recharge was measured. Within eight minutes of shut down, <br /> groundwater levels had rebounded from 15.40 to 13.70 feet bgs and approximately 13.70 feet <br /> bgs was maintained for an additional three readings over a 15 minute period until the <br /> submersible pump was restarted. Restart at 12:01 pm was followed by 16 minutes of GWE to <br /> 1,000 gallons total production (additional 43 gallons). The submersible was then shut down due <br /> to low groundwater production and recharge was measured. Within 85 minutes of that shut <br /> down, groundwater levels had rebounded from 15.02 to the 13.77 feet bgs (similar to the first <br /> rebound test). Approximately 13.30 feet bgs was maintained over a 20.2 hour period. GWE-1 <br /> was never restarted again. Note that the first rebound period identified above occurred with <br /> GWE-2 off and the second period was initiated when GWE-2 was on and extracting <br /> groundwater approximately 112 feet down slope of GWE-1 in the GCT. <br /> During GWE on GWE-1, the following selected chemical constituent mass was removed: <br /> • Approximately 0.013 lbs of TPHd were removed at a removal rate of 0.11 lbs/day. At <br /> <2.0 gpm that is a projected removal rate of less than 0.04 lbs/day. <br /> • Approximately 0.002 lbs of TPHg were removed at a removal rate of 0.02 lbs/day. At <br /> <2.0 gpm that is a projected removal rate of less than 0.01 lbs/day. <br /> • Approximately 4.5E-6 lbs of benzene were removed at a removal rate of 3.6E-5 lbs/day. <br /> At <2.0 gpm that is a projected removal rate of less than 1.3E-5 lbs/day. <br /> • Approximately 3.0E-4 lbs of TBA were removed at a removal rate of 2.3E-3 lbs/day. At <br /> <2.0 gpm that is a projected removal rate of less than 8.6E-4 lbs/day. <br /> GWE analytical data are presented in Table 5 and calculations of mass removal by GWE are <br /> presented in Table 7. Laboratory analytical reports and chain-of-custody documentation are <br /> included in Appendix I. <br /> 4.7 GWE-2 GROUNDWATER EXTRACTION TESTS DATA AND RESULTS <br /> GWE-2 was operated in the GWE mode for approximately 6.2 hours between November 16 and <br /> 17, 2010. Field notes are included in Appendix H. The following is a summary of the data <br /> collected during the test. <br /> The average GWE rate for GWE-2 was approximately 5.4 gpm with a total production of 2,041 <br /> gallons. Groundwater production rates decreased to approximately <4.0 gpm by the end of the <br /> test. Groundwater extraction data is presented in Table 3. <br /> The inlet of the submersible pump was set at approximately 15 feet bgs inside GWE-2. The <br /> depth-to-water prior to extraction was 13.02 feet bgs. During the GWE test on GWE-2, <br /> groundwater elevations in two wells (GWE-1 and MW-72) were monitored. Groundwater <br /> drawdown of any significance was not observed in MW-72 during the test; however; extracting <br /> 4.9 <br />