Laserfiche WebLink
Stantec <br /> Report of Findings for the Waterfront Towers Separate Phase Hydrocarbon Investigation <br /> and Unocal Extraction Well Pilot Study <br /> Waterfront Towers Parking Lot <br /> March 4, 2011 <br /> GCT towards GWE-1 and then down to GWE-2 and eventually south toward the Mormon <br /> Slough. The GWE test results show higher sustained groundwater recovery from GWE-2 than <br /> GWE-1, which is likely because GWE-2 is located near the bottom of the GCT. Groundwater <br /> recovery rates observed in GWE-1 and GWE-2 are similar and not higher than groundwater flow <br /> rates observed in other four-inch diameter nearby wells historically tested on the L&M OU site. <br /> The projected design groundwater flow rates and pressures are as follows: <br /> • Design of pumping groundwater from GWE-1 should anticipate peak flows of at least 7.0 <br /> gpm and sustained flows of around <2.0 gpm. Head pressure against any pump installed <br /> in GWE-1 would be approximately 15 feet of water plus additional head losses from pipe <br /> and pipe components. <br /> • Design of pumping groundwater from GWE-2 should anticipate peak flows of at least 6.3 <br /> gpm and sustained flows of around <4.0 gpm. Head pressure against any pump installed <br /> in GWE-2 would be approximately 15 feet of water plus additional head losses from pipe <br /> and pipe components. <br /> • Combined groundwater recovery system and treatment system should anticipate peak <br /> groundwater flows of approximately 13.32 gpm with sustained flows of less than six gpm <br /> from GWE-1 and GWE-2 combined. Note that TPE testing (which followed pump testing) <br /> indicates that groundwater production was substantially reduced following the pump test <br /> portion of these tests. This indicates that higher flows during the pump test portion may <br /> have consisted of storage in the UOU excavation and GCT and is not representative of <br /> long term groundwater production, which may be substantially reduced. <br /> Combined groundwater treatment system should take into account total hydrocarbon <br /> loadings. <br /> Soil vapor extraction from GWE-1 and GWE-2 should be initiated because those activities may <br /> help to recover chemical mass from the UOU and maintain the cleanliness of fill material placed <br /> there by the SRDA following excavation activities. <br /> The projected design SVE flow rates and pressures are as follows: <br /> • Design of SVE from GWE-1 should anticipate peak vapor flows of around 174 scfm. <br /> Applied casing vacuum would have to be at least 1.3 in. H2O gauge vacuum pressure <br /> plus additional head losses from pipe and pipe components. <br /> • Design of SVE from GWE-2 should anticipate peak vapor flows of around 148.9 scfm. <br /> Applied casing vacuum would have to be at least 16.2 in. H2O gauge vacuum pressure <br /> plus additional head losses from pipe and pipe components. <br /> Combined SVE recovery and vapor abatement systems for GWE-1 and GWE-2 should <br /> anticipate peak flows of approximately 400 scfm and be capable of generating the 400 <br /> scfm at a minimum of 16.2 in H2O gauge vacuum pressure <br /> 4.14 <br />