Laserfiche WebLink
`✓ - Yr?e�,t Q12 i12Vll'OI'lli2�ilii2i V� V01'� <br /> WORK ORDER: 9710362 QUALITY CONTROL REPORT PAGE QR-3 <br /> ANALYSIS: Gasoline Oxygenates <br /> MATRIX: Water <br /> MATRIX SPIKE DUPLICATES <br /> ................... ...... ........ .....................6w SAMPLE TYPE: Spiked Sample Duplicate LAB ID: MR10362-05C INSTR RUN: GCMS13\971108000000/10/8 <br /> INSTRUMENT: HP mass spec for Volatiles PREPARED: BATCH ID: MS13W110897 <br /> UNITS: ug/L ANALYZED: 11/08/97 DILUTION: 1.00 <br /> METHOD: <br /> REF REPORTING SPIKE RECOVERY REC LIMITS (X) RPD <br /> ANALYTE RESULT RESULT LIMIT VALUE (Z) LOW HIGH RPD (;) LIMIT (X) <br /> 1.2-DCE-d4 (surr) 107 127 100 100 107 70 130 <br /> Toluene-d8 (surr) 96.2. 91.6 100 100 96.2 70 130 <br /> Bromofluorobenzene (surr) 101 103 100 100 101 70 130 <br /> Methy-t-butyl ether (MTBE) 115 145 5 23.1 25 <br /> Ethyl-t-butyl ether (ETRE) 128 163 5 24.1 25 <br /> t-Amylmethyl ether (TAME) 122 148 5 19.3 25 <br /> ............................................................................................. <br /> SAMPLE SURROGATES <br /> ----------------------------------------------------------------------------------------------------------------------------- <br /> SAMPLE TYPE: Sample-Client LAB ID: 9710362.01C INSTR RUN: GCMS13\971108000000/3/ <br /> INSTRUMENT: HP mass spec for Volatiles PREPARED: BATCH ID: M513W110897 <br /> UNITS: ug/L ANALYZED: 11/08/97 DILUTION: 1.00 <br /> METHOD: <br /> REF REPORTING SPIKE RECOVERY REC LIMITS (X) RPO <br /> ANALYTE RESULT RESULT LIMIT VALUE (X) LOW HIGH RPD (X) LIMIT (X) <br /> 1,2-DCE-d4 (surr) 98.6 100 100 98.6 70 130 <br /> Toluene-d8 (surr) 100 100 100 100 70 130 <br /> Bromofluorobenzene (surr) 105 100 100 105 70 130 <br /> ---------------------------------------------------------------------------------- ------------------------------------------ <br /> ------------------------------------------------------------------------------------------------------------------------ ---- <br /> SAMPLE TYPE: Sample-Client LAB ID: 9710362-02C INSTR RUN: GCMS13\971108000000/4/ <br /> INSTRUMENT: HP mass spec for Volatiles PREPARED: BATCH ID: MS13W110897 <br /> UNITS: ug/L ANALYZED: 11/08/97 DILUTION: 1.00 <br /> METHOD: <br /> REF REPORTING SPIKE RECOVERY REC LIMITS (X) RPD <br /> ANALYTE RESULT RESULT LIMIT VALUE (X) LOW HIGH RPD (X) LIMIT (X) <br /> 1,2-DCE-d4 (surr) 115 100 100 115 70 130 <br /> Toluene-d8 (surr) 93.4 100 100 93.4 70 130 <br /> Bromofluorobenzene (surr) 104 100 100 104 70 130 <br /> y ............................................................................................................................. <br /> ............................................................................................................................. <br /> SAMPLE TYPE: Sample-Client LAB ID: 9710362-03C INSTR RUN: GCMS13\971108000000/5/ <br /> INSTRUMENT: HP mass spec for Volatiles PREPARED: BATCH ID: MS13W110897 <br /> UNITS: ug/L ANALYZED: 11/08/97 DILUTION: 1.00 <br /> METHOD: <br /> REF REPORTING SPIKE RECOVERY REC LIMITS (X) RPD <br /> ANALYTE RESULT RESULT LIMIT VALUE (X) LOW HIGH RPD (X) LIMIT (X) <br /> 1.2-DCE-d4 (surr) 116 100 100 116 70 130 <br /> Toluene-d8 (surr) 98.0 100 100 98.0 70 130 <br /> Bromofluorobenzene (surr) 104 100 100 104 70 130 <br /> ----------------------------------------------------------------------------------------------------------------------------- <br /> ............................................................................................................................. <br /> SAMPLE TYPE: Sample-Client LAB ID: 9710362-04C INSTR RUN: GCMS13\971108000000/6/ <br /> INSTRUMENT: HP mass spec for Volatiles PREPARED: BATCH ID: MS13W110897 <br /> UNITS: ug/L ANALYZED: 11/08/97 DILUTION: 1.00 <br /> METHOD: <br /> REF REPORTING SPIKE RECOVERY REC LIMITS (X) RPD <br /> ANALYTE RESULT RESULT LIMIT VALUE (X) LOW HIGH RPD (X) LIMIT (X) <br /> 1.2•DCE-d4 (surr) 101 100 100 101 70 130 <br /> Toluene-d8 (surr) 99.4 100 100 99.4 70 130 <br /> Bromofluorobenzene (surr) 105 100 100 105 70 130 <br /> -------------------------------------------------------------------------------------------------------------------------- <br /> ----------------------------------------------------------------------------------------------------------------------------- <br /> '" SAMPLE TYPE: Sample-Client LAB ID: 9710362.05C INSTR RUN: GCMS13\971108000000/7/ <br /> INSTRUMENT: HP mass spec for Volatiles PREPARED: BATCH ID: MS13W110897 <br /> UNITS: ug/L ANALYZED: 11/08/97 DILUTION: 1.00 <br /> METHOD: <br /> REF REPORTING SPIKE RECOVERY REC LIMITS (X) RPD <br /> ANALYTE RESULT RESULT LIMIT VALUE (X) LOW HIGH RPD (X) LIMIT (X) <br /> 1.2-DCE-d4 (surr) 105 100 100 105 70 130 <br /> Toluene-d8 (surr) 96.7 100 100 96.7 70 130 <br />