b <br /> NIFIED PROGRAM CONSOLIDATED FORI TANK: TA0143303 <br /> PR#: PR0231433 <br /> FAC#: FA0003685 <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br /> VL PIPING CONSTRUCTION(Check all that apph) Page 7 of 7 <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE ® 1.PRESSURE ❑ 2.SUCTION ❑3.GRAVITY 458 ❑ 1.PRESSURE ❑2.SUCTION ❑3.GRAVITY 459 <br /> CONSTRUCTION ❑1.SINGLE WALL ❑3.LINED TRENCH ❑99.OTHER 46a ❑ 1.SINGLE WALL ❑95.UNKNOWN 462 <br /> ®2.DOUBLE WALL 095.UNKNOWN ❑2.DOUBLE WALL ❑99.OTHER <br /> MANUFACTURER RED THREAD 461 MANUFACTURER 463 <br /> ❑ 1.BARE STEEL ❑ 6.FRP COMPATIBLE w/IWI.METHANOL ❑ 1.BARE STEEL ❑6.FRP COMPATIBLE w/100%METHANOL <br /> ❑2.STAINLESS STEEL ❑ 7.GALVANIZED STEEL ❑2.STAINLESS STEEL ❑ 7.GALVANIZED STEEL <br /> ❑ PLASTIC COMPATIBLE W/CONTENTS ❑ 95.UNKNOWN ❑ PLASTIC COMPATIBLE W/CONTENTS ❑95.UNKNOWN <br /> [914.FIBERGLASS ❑ 8.FLEXIBLE(HDPE) ❑ 99.OTHER ❑4.FIBERGLASS ❑ 8.FLEXIBLE(HDPE) ❑99.OTHER <br /> ❑ 5.STEEL W/COATING ❑ 9.CATHODIC PROTECTION 464 ❑ 5.STEEL W/COATING ❑9.CATHODIC PROTECTION 465 <br /> VIL PIPING LEAK DETECTION(Check,all that apply)(A descriptim of the monitoring program shall be submitted to the local agency.) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING 467 <br /> PRE URIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 1.1.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF ❑ I.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF <br /> FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND <br /> VISUAL ALARMS. VISUAL ALARMS. <br /> ❑ 2.MONTHLY 0.2 GPH TEST ❑2.MONTHLY 0.2 GPH TEST ❑ 3.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> 2r3.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑4.DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check all that apply) <br /> ❑5.DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIEAL PIPING ❑5.DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> INTEGRITY TEST(0.I GPH) ❑6.TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING): SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPTNG): <br /> ❑ 7.SELF MONITORING <br /> ❑ 7.SELF MONITORING <br /> GRAVITY FLOW <br /> ❑9.BIENNIAL INTEGRITY TEST(0.1)GPH <br /> GRAVITY FLOW(Check all that appy): <br /> ❑ 8.DAILY VISUAL MONITORING <br /> ❑ 9.BIENNIAL INTEGRITY TEST(0.1)GPH <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that appy): <br /> 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br /> ALARMS AND(Check one) ALARMS AND(Check ane) <br /> ❑ a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑a AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> E]b-AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION <br /> DISCONNECTION <br /> ❑c. NO AUTO PUMP SHUT OFF ❑c.NO AUTO PUMP SHUT OFF <br /> ® 11.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR ❑ 11 AUTOMATIC LEAK DETECTOR <br /> RESTRICTION <br /> ❑ 12.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 12.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCIION/GRAN TrY SYSTEM SUCTION/GRAVITY SYSTEM <br /> ❑ 13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that appy) EMERGENCY GENERATORS ONLY(Check all that appy) <br /> ❑ 14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF• ❑ 14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF <br /> AUDIBLE AND VISUAL ALARMS AUDIBLE AND VISUAL ALARMS <br /> ❑ 15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW ❑ 15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW <br /> SHUT OFF OR RESTRICTION SHUT OFF OR RESTRICTION <br /> ❑ 16.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 16.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 17.DAILY VISUAL CHECK ❑ 17.DAILY VISUAL CHECK <br /> VIL DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT ® 1.FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑4.DAILY VISUAL CHECK <br /> DATE INSTALLED 468 ❑ 2.CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑5.TRENCH LINER/MONITORING <br /> ❑3.CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR ❑6.NONE <br /> DISPENSER+AUDIBLE AND VISUAL ALARMS 469 <br /> DL OWNER/OPERATOR SIGNATURE <br /> I certify that the information provided herein is nue and accurate to the best of my knowledge. <br /> SIGNATURE OF RRA DATE 470 <br /> /`'(*/ 5/J10.1 <br /> NAME OF OWNER/OPERATOR(print) 1/t t/ T n A��d� TITLE OF OWnNERRIOP[ERRALT�OIR /Y� /��//��+I(n <br /> .)AtE'Sb7E'f M I�(�L/ 1 �J/N // 47� t77C&PR&7'5ENT OU •✓1` 47' <br /> F <br /> it Number(For local use only) 473 Pemnit Approved(For local use only) ice'474 Permit Expiration Date(Fa local use only) 47s <br /> PT0004080 EE0003804 12/31/2007 12:00:OOAM <br /> UPCF(12/99 revised) <br />