05/13/97 TUE 15:35 FAX 9166488052_ SECOR-SACRAMENTO Z005 <br /> i <br /> i I <br /> � I <br /> TABLE V <br /> f <br /> i <br /> RECOMMENDATIONS I <br /> i <br /> SECOR recommends thalt a total of three soil borings, SB-1 through S13-3 (Figure 3), be drilled at the <br /> site in conjunction with The environmental and geotechnical investigations. One boring each will be <br /> located in the proposed building pad area, the proposed pump island canopy area and the area of the <br /> proposed USTs. Soil borings SB-2 and SB-3 will be completed to a depth of approximately 20 feet <br /> bgs. Soil boring SB-1 will be completed to a depth of approximately 50 feet bgs. SB-I will be utilized <br /> to evaluate liquefaction potential for subsurface soils beneath the property because of shallow <br /> groundwater (7 to 10 fxt bgs). It is also recommended that a minimum of f...r groundwater <br /> monitorrmg wells be installed (MW-1, MW-2,aI MW- to evaluate if shallow groundwater beneath l <br /> the property has been impacted by offsite sources (refe to Table N, Surrounding Land Use). <br /> Item' Itcummeadatian y Ynrt'Cnsts° <br /> #of Borings 4 geotm hnicaVenviroamental borings Some additional job costs for liquefaction analysis <br /> 3 groundwater monitoring wells and groundwater monitoring well installation. <br /> I <br /> Analysis TPHg TPHd,TRPH Standard job costs. No additional costs. <br /> BTEX.,MTBE <br /> I <br /> VOCs <br /> i <br /> . y <br /> I <br /> 1� <br /> V-1 <br /> 1N 40007-130-01 <br /> karlwinwordi97.04apr4-racy.doc <br /> i <br />