S A N J O A Q U I N Environmental Health Department <br /> COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> DBA CIRCLEK, REFUEL PETROLEUM INC. 419 S MAIN ST, MANTECA May 21, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. For the 91-product and diesel-product tanks, <br /> the monitoring plan indicates the manufacturer of the mechanical leak detectors as Veeder root. The manufacturer <br /> should be changed to Red Jacket for both product tanks. The monitoring plan must be uploaded to the California <br /> Environmental Reporting System(CERS). Immediately log into CERS, make the necessary changes, and submit <br /> for review by the EHD. <br /> This is a repeat violation, Class II. <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted.The site plan is missing the layout of the piping.A site <br /> plan must be submitted identifying the locations where monitoring will be performed. Immediately log into the <br /> California Environmental Reporting System(CERS)at http://cers.calepa.ca.gov/and upload a copy of the UST <br /> Monitoring Site Plan. <br /> This is a repeat violation, Class II. <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to check and note the correct test dates for the May 2017 through April 2018 <br /> designated operator monthly inspection report.The secondary containment test date was noted as 5/26/16 and <br /> should be 5/26/15. During the monthly inspection,the designated operator shall check that all required testing and <br /> maintenance for the UST system have been completed and document the dates they were done. Ensure that <br /> designated operators performing monthly inspections at this facility are including all of the required information on <br /> the reports. <br /> This is a repeat violation, Class ll. <br /> 211 CCR 2715(f)(2) Designated operator employee training not performed or log not kept. <br /> The designated operator employee training for Dorrene Ripley was not performed. The designated operator shall <br /> train facility employees for which he or she is responsible in the proper operation and maintenance of the UST <br /> system once every 12 months. The training shall include, but is not limited to: <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s)for emergencies and monitoring equipment alarms <br /> Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of <br /> the training records to the EHD. <br /> This is a minor violation. <br /> FA0003685 PR0231433 SCO01 05/21/2018 <br /> EHD 23-01 Rev.10/31/2017 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />