My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005 - 2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
419
>
2300 - Underground Storage Tank Program
>
PR0231433
>
COMPLIANCE INFO_2005 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/19/2020 4:59:42 PM
Creation date
2/19/2020 10:50:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2009
RECORD_ID
PR0231433
PE
2361
FACILITY_ID
FA0003685
FACILITY_NAME
DBA CIRCLEK, REFUEL PETROLEUM INC.
STREET_NUMBER
419
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21938610
CURRENT_STATUS
01
SITE_LOCATION
419 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
347
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,.lanuary 2002 Page _of <br /> _ 7. UNDER-DISPENSER CONTAINMENT (UDC)TESTLNG <br /> Test Me&)d Developed By: ❑UDC Manufacturer ^[ndustry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Met ad Used: ❑Pressure ❑Vacuum ACHydrostatic <br /> ❑Other(Spec) <br /> "fest Equi�)ment Used: INCON TS STS Equipment Resolution: .000 1" <br /> UDC#3-4 UDC# UDC# UDC# <br /> UDC Mai:ufacturer:� BRAVO <br /> UDC Material: STEEL <br /> UDC Depth: 11 <br /> i Height from UDC Bottom to Top 0 <br /> of Hi hest.Piping Penetration: <br /> Height from UDC Bottom to 0 <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to GOOD <br /> testing: _ <br /> Portion of UDC Tested 2" <br /> Does turb ane shut down when <br /> UDC sent;or detects liquid(both ❑Yes ❑No ❑NA ❑Yes :]No NA I Yes ❑No ❑NA 7�Yes No ❑NA <br /> product a;:id water)?* <br /> Turbine shutdown res onse time <br /> Is system programmed for fail- ❑Yes ❑No ENA ❑Yes ❑No DNA ❑Yes No ,NA 0 Yes ❑No :1 NA <br /> safe shutdown? <br /> Was fail-safe verified to be ❑Yes ❑No ❑NA ❑Yes ❑No [INA ❑Yes []No ❑NA -]Yes ❑No ❑NA <br /> operation Ll?* <br /> Wait time between applying <br /> pressure/,:acuum/water and <br /> startingtest <br /> Test Start Time: 1427 <br /> Initial ReadingRt : 2.3362 <br /> Test End Time: 1442 <br /> Final Reader F): 2.3358 <br /> Test Duration: 15 min <br /> Change in Reading(RF-Rt): .0004 <br /> Pass/Fail Threshold or Criteria: .002 <br /> Test Result: ($ Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? E Yes ❑No kNA ❑Yes ❑No ❑NA ']Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and _Yes ❑No 4 N ❑Yes 7 No ❑NA F-Yes ❑No ❑NA LJ Yes 7 No C NA <br /> verifted f.mctional after testing? <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> Sealed Electrical conduits using CARB approved and BRAVO approved sealant Vulkem 116 <br /> If the en-ire depth of the UDC is not tested,specify how much was tested. If the answer to My of the questions indicated with an <br /> asterisk(')is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.