amecwO <br /> Mr. Howard Hold <br /> California Regional Water Quality Control Board <br /> Central Valley Region <br /> April 27, 2010 <br /> Page 6 <br /> (10 pg/L) in the groundwater samples from well LPW-3. The reported concentrations of total <br /> and dissolved Cr were below the CDPH MCL of 50 pg/L and within the range of concentrations <br /> detected during previous events. <br /> Dissolved Cr VI was detected in the groundwater samples from monitoring wells LPW-1 <br /> (cross-gradient), LPW-2 (downgradient), and LPW-3 (upgradient) at concentrations of <br /> 7.5, 14, and 3.5 pg/L (LPW-3 duplicate at 3.4 pg/L), respectively. The reported concentrations <br /> of dissolved Cr VI in the groundwater samples were below the CDPH MCL of 50 pg/L and within <br /> the range of concentrations detected during previous events. <br /> January 2010 <br /> Total Cr was detected in the groundwater samples from monitoring wells LPW-1 and LPW-2 at <br /> concentrations of 5.OJ and 13 pg/L, respectively. Dissolved Cr was detected in the groundwater <br /> samples from wells LPW-1 and LPW-2 at concentrations of 4.3J and 11 pg/L, respectively. <br /> Total and dissolved Cr were not detected above the laboratory reporting limit (10 pg/L) in the <br /> groundwater samples from well LPW-3. The reported concentrations of total and dissolved Cr <br /> were below the CDPH MCL of 50 pg/L and within the range of concentrations detected during <br /> previous events. <br /> Dissolved Cr VI was detected in the groundwater samples from monitoring wells LPW-1 <br /> (cross-gradient), LPW-2 (downgradient), and LPW-3 (upgradient) at concentrations of <br /> 6.3, 13, and 2.9 pg/L (LPW-3 duplicate at 2.8 pg/L), respectively. The reported concentrations <br /> of dissolved Cr VI in the groundwater samples were below the CDPH MCL of 50 pg/L and within <br /> the range of concentrations detected during previous events. <br /> February 2010 <br /> Total Cr was detected in the groundwater samples from monitoring wells LPW-1 and LPW-2 at <br /> concentrations of 3.7J and 11 pg/L, respectively. Dissolved Cr was detected in the groundwater <br /> samples from wells LPW-1 and LPW-2 at concentrations of 3.5J and 11 pg/L, respectively. <br /> Total and dissolved Cr were not detected above the laboratory reporting limit (10 pg/L) in the <br /> groundwater samples from well LPW-3. The reported concentrations of total and dissolved Cr <br /> were below the CDPH MCL of 50 pg/L and within the range of concentrations detected during <br /> previous events. <br /> Dissolved Cr VI was detected in the groundwater samples from monitoring wells LPW-1 <br /> (cross-gradient), LPW-2 (downgradient), and LPW-3 (upgradient) at concentrations of 5.0, 13, <br /> and 7.1 pg/L (LPW-3 duplicate at 6.8 pg/L), respectively. The reported concentrations of <br /> dissolved Cr VI in the groundwater samples were below the CDPH MCL of 50 pg/L and within <br /> the range of concentrations detected during previous events. <br /> PA10626.000.0\Docs\Semi-Annual Groundwater Monitoring&SamplingIathrop Monthly Groundwater Monitoring\Ltr_042710.doc <br />