Laserfiche WebLink
APPLICATION - QUARRY EXCAVATION <br /> SAN JOAQUIN COUNTY COMMUNITY DEVELOPMENT DEPARTMENT <br /> 9� <br /> FILE NUMBER: QX- <br /> ii Z5 <br /> RECLAMATION SITE PLAN <br /> CHECK LIST <br /> • Size: The Excavation and Reclamation Plans shall be drawn on 24"x 36" reproducible material. <br /> • Owners of Mineral Interest: The Names and Addresses of the owners of all surface mineral interests of the property. <br /> • North Arrow, Date and Scale: Use an engineer's scale (i.e., 1"to 20'or 1"to 100'). The direction of"north"should be pointing <br /> towards the top of the page. <br /> • Vicinity Map and Haul Routes: A vicinity map showing the location of the project site and proposed haul routes. <br /> • Streets and Easements: Location and names of all streets and easements bordering on the property with access details. <br /> • Project Boundary: The extent of the area to be excavated. <br /> • Property Lines: All property lines or boundary lines of the parcel with dimensions. <br /> • Watercourses and Flooding: The location of all areas on the property subject to inundation or flooding and the location,width and <br /> direction of flow of all watercourses and flood control channels which may be affected by the excavation. <br /> • Topography: Bench marks and topographic details of the site. <br /> • Existing and Proposed Development: All existing structures(labeled'existing')and any proposed structures(labeled'proposed') <br /> with dimensions, square footage and distances from other structures and property lines. Any existing structures planned for <br /> removal should be shown with dashed lines. The use and number of floors should be labeled on each structure. Structures include <br /> utility lines, processing plants and irrigation facilities, as well as buildings. <br /> • Parking and Driveways: The location, dimensions and surface material of all existing and proposed parking and driveways. <br /> Calculations indicating the number of required spaces must be shown. (Refer to'County Parking Lot Standards'). <br /> • On-site Roads: All access roads and proposed surfacing. <br /> • Stockpiling: Areas to be used for stockpiling the topsoil or overburden and/or the material to be removed from the property. <br /> • Water Wells: The location of existing and proposed water wells on-site and any off-site wells within 150'of the proposed <br /> development. Wells must be meet the following setbacks: <br /> - 5'from structures; <br /> - 50'from septic tanks; <br /> - 100'from leach lines; <br /> - 150'from sumps or seepage pits;and <br /> - 10'from property lines. <br /> I If public water will be utilized.,a"will-serve"letter must be submitted from the service provider. <br /> • Sewers and Septic Tanks: The location of the sewer outlet, public sewer hook-up,or existing and proposed sewage disposal <br /> systems and any off-site sewage disposal systems within 150'of the property. <br /> Septic tanks must meet the following setbacks: <br /> - 5'from property lines, structures, m driveways and swimming pools; <br /> - 50'from water wells. <br /> Leach lines must meet the following setbacks: <br /> - 10'from structures,driveways and swimming pools; <br /> - 100'from wells, streams and waterways. <br /> - 5'to 75'from property lines depending on zoning or the location of septic systems on adjoining properties(this requirement also <br /> applies to seepage pits). <br /> If public sewage disposal will be utilized,a"will-serve" letter must be submitted from the service provider. <br /> • Storm Drainage: The location of existing and proposed storm drainage faciIities(check with Engineering staff regarding design <br /> criteria). <br /> • Signs, Fences, Storage and Trash Enclosures: The location of and height of all existing and proposed signs and fences and the <br /> location and dimensions of all open and/or enclosed storage and trash receptacles. <br /> F:\DEVSVC\Planning Application Forms\ Page 19 of 19 <br /> Quart'Excavation.doc.(Revised 02-03-10) <br />