Laserfiche WebLink
VERTICAL DISCHUGE SERIACOMMUNICATION <br /> Another unique feature of FE Petro. Provides Incorporates a RS 485 <br /> for a simple connection to underground piping. serial communications <br /> system for easy <br /> integration or remote ' <br /> \ monitoring. <br /> u <br /> o-,sik <br /> t. <br /> System integration with other electronic <br /> monitoring equipment. <br /> This unique FE Petro feature allows for fewer <br /> fittings to connect the pump to the discharge <br /> line,and requires less space in the sump. <br /> SIMPLE SERVICING Power Requirements: <br /> If ever required, Variable Frequency Controller Input Power <br /> the pump can be 200/250 Volt,l or 3 phase,50 or 60 Hz <br /> easily removed Motor <br /> from the tank by Three phase,power provided by variable <br /> frequency controller. <br /> unthreading Pump Motor: <br /> three bolts.There 2 HP,2 stage centrifugal pump <br /> is no need to Maximum liquid viscosity: <br /> disconnect the 70 SSU at 60 deg F, <br /> syphon system, capable of pumping ballast water from <br /> underground tanks. <br /> or remove the Maximum flow rate-100 GPM at full flow <br /> leak detector Maximum Pressure-126 feet of head <br /> from the system (42 PSI in gasoline) <br /> to service the IST. Maximum Amperage-9 amps at full load <br /> Check Valve: <br /> •2 3/4"(70mm)diameter constructed of Alcohol <br /> compatible alodined aluminum and steel <br /> This feature reduces the risk of correcting with fluorocarbon seal. <br /> one problem and causing another. Pressure Relief Valve: <br /> Set to relieve static line pressure at 40-50 PSI, <br /> reseals above 20 PSI. <br /> INTELLIGENCE: Seal Elastomers: <br /> The Variable Frequency Controller has contin- •All wetted seals are Fluorocarbon. <br /> uous running diagnostics and displays system Syphon: <br /> conditions Ori the controller. Syphon Primer is venturi type,capable <br /> of 26"Hg vacuum <br /> Dry Running — Syphon Check Valve is machined aluminum. <br /> Low Incoming Voltage _ - field repairable <br /> Locked Rotor in Pump - Variable Frequency Controller Size: <br /> Open Circuit between Enclosure Size is 51/8"wide by 10"high <br /> Controller and Motor by 81/4"deep <br /> Alcohol/Gasoline Compatible: <br /> Short Circuit between FE,WnWi •A standard feature.The IST will handle any <br /> Controller and Motor mixture of alcohol in gasoline,up to 100`',, <br /> Thermal Overload in Controller methanol or ethanol,and up to 20%MTBE, <br /> Controller capacitors failing 20%ETBE,or 17%TAME. <br /> Approvals: <br /> •UL,others pending <br /> Immediate,easily understood,display of Quality Certification: <br /> FE Petro is an ISO 9001 Certified manufacturer. <br /> system conditions. <br />