Laserfiche WebLink
1 <br /> 1.0 INTRODUCTION <br /> This quarterly monitoring report was prepared by American Geological Services, Inc for <br /> Western Refrigerating and Cold Storage Company As part of the ongoing quarterly <br /> Imonitoring and site investigation program, this report details all field activities performed <br /> on December 21, 1995 at the Tracy Cold Storage site and the results of these activities <br /> The following sections describe the methodology employed and the results obtained <br /> during this sampling event Historical ground water analytical data is also provided for <br /> each of the previous sampling events <br /> 1 1 Site Description <br /> The Tracy Cold Storage site is located at 24500 S MacArthur Road in Tracy, California <br /> (Figure 1) The property includes approximately eight acres of land which is utilized as a <br /> commercial cold storage facility for agricultural products The site is bounded on three <br /> sides by undeveloped agricultural land The northern boundary of the property is shared <br /> with the Southern Pacific Railroad No residences are located within 1,000 feet of the <br /> I site <br /> Approximately 44,000 square feet of cold storage space, various maintenance buildings, <br /> and an office are located on the property Water is supplied by two on-site wells A <br /> septic system is located on-site <br /> 12 Site Background <br /> Remcor, Inc of Pittsburgh, Pennsylvania, conducted an environmental assessment in <br /> May, 1994 to determine the current environmental condition of the site Remcor's report, <br /> dated July 21, 1994, indicated that the potential for soil or ground water contamination <br /> existed at several locations on the property Of primary concern was a former <br /> underground gasoline storage tank that had been removed in the 1970's No information <br /> regarding tank condition, possible soil or ground water contamination, or subsequent <br /> investigations was provided, however, it was reported that the tank was removed because <br /> it was known to be leaking <br /> On August 4 and 5, 1994, Remcor supervised the drilling of seven soil borings Three of <br /> the borings were completed as ground water monitoring wells Both soil and ground <br /> water samples were collected for analysis of suspected or potential contaminants Based <br /> upon the information obtained during this investigation, it was determined that an impact <br /> 1 <br /> . American Geological Services, Inc <br /> CA95DE-029 <br /> I1 <br /> 1 <br />