Laserfiche WebLink
Analysis Report <br /> Lancaster Laboratories Page 2 of 3 <br /> Wh #tjzYa9qMkr01 Summary <br /> Client Name ChevronTexaco Group Number 816683 <br /> Reported 08/15/02 at 08 32 AM <br /> Sample Matrix Quality Control <br /> MS NSD HS/N8D RPD BRCS DUP DVP DuP <br /> RPD <br /> Anal sis Name %REC %REC Limits RPD MAX CDnc Conc RPD Max <br /> Ethyl t-butyl ether 96 97 73-123 2 30 <br /> t-Amyl methyl ether 95 95 69-118 0 30 <br /> t-Butyl alcohol 88 Be 51-148 0 30 <br /> Benzene 105 105 78-134 0 30 <br /> Toluene 104 103 83-127 O 30 <br /> Ethylbenzene 107 107 82-134 0 30 <br /> Xylene (Total) 109 110 82-130 O 30 <br /> Batch number P022212AB Sample number(s) 3865233,3865235-3865243 <br /> Ethanol 71 76 34-163 6 30 <br /> Methyl t-butyl ether 95 94 69-134 1 30 <br /> d1-Isopropyl ether 92 93 68-133 0 30 <br /> Ethyl t-butyl ether 96 97 73-123 2 30 <br /> t-Amyl methyl ether 95 95 69-118 0 30 <br /> t-Butyl alcohol 88 88 51-148 0 30 <br /> Benzene 145 105 78-134 0 30 <br /> Toluene 104 103 83-127 0 30 <br /> Ethylbenzene 107 107 62-134 0 30 <br /> Xylene (Total) 109 110 82-130 0 30 <br /> Surrogate Quality Control <br /> Analysis Name TPH-GRO - Waters <br /> Batch number 0221OA56A <br /> Trifluorotoluene-F <br /> 3865233 86 <br /> 3865234 82 <br /> 3865235 120 <br /> 3865236 83 <br /> 3865237 81 <br /> 3865239 84 <br /> 3865240 87 <br /> 3865241 85 <br /> 3865242 85 <br /> 3865243 85 <br /> Blank 85 <br /> LCS 95 <br /> LCSD 92 <br /> MS 101 <br /> Limits 57-146 <br /> Analysis Name TPH-GRO - Waters <br /> Batch number 0221OA56B <br /> *- Outside of specification <br /> {1) The result for one or both determinations was less than five times the LOQ <br /> The background result was more than four times the spike added <br /> Lancaster Laboratories Inc <br /> M E M B E R 2425 New Holland Pike <br /> PO Box 12425 <br /> Lancaster 12425 <br /> 717-656 230000 Fax Fax 717-656 2681 2216 Rev 9111!00 <br />