a <br /> Lancaster <br /> • Laboratories <br /> Page 3 of 5 <br /> Quality Control Sununary <br /> Client Name ChevronTexaco Group Number 839185 <br /> Reported 02/12/03 at 02 58 PM <br /> Surrogate Quality Control <br /> Batch number 03025A0'7C <br /> Trifluorotoluene-F <br /> 3984038 93 <br /> Blank 95 <br /> LCS 109 <br /> LCSD 109 <br /> MS 116 <br /> Limits 57-146 <br /> Analysis Name TPH-GRO - Waters <br /> Batch number 0302BA07C <br /> Trifluorotoluene-F <br /> 3984039 99 <br /> Blank 90 <br /> LCS 111 <br /> LCSD 113 <br /> MS 113 <br /> 1tS 57-146 <br /> Analysis Name TPH-GRO - Waters <br /> Batch number 03028A53A <br /> Trifluorotoluene-F <br /> 3984040 153* <br /> 3984041 102 <br /> 3984042 105 <br /> 3984044 98 <br /> 3984045 103 <br /> 3984046 99 <br /> 3984047 101 <br /> 3984048 106 <br /> Blank 102 <br /> LCS 103 <br /> LCSD 102 <br /> Ms 106 <br /> Limits 57-146 <br /> Analysis Name TPH-GRO - Waters <br /> Batch number 0302BA53B <br /> Trifluorotoluene-F <br /> 3984043 110 <br /> Blank 99 <br /> * Outside of specification <br /> (1) The result for one or both determinations was less than five tunes the LOQ <br /> The background result was more than four times the spike added <br /> Lancaster Laboratories Inc <br /> M E M B E R 2425 New Holland Pike <br /> PO Box 12425 <br /> Lancaster PA 17605 2425 <br /> 717-656 2300 Fax 717-656 2681 <br />