My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FIELD DOCUMENTS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
2795
>
2900 - Site Mitigation Program
>
PR0516577
>
FIELD DOCUMENTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2020 11:57:24 AM
Creation date
3/4/2020 11:23:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
FIELD DOCUMENTS
RECORD_ID
PR0516577
PE
2950
FACILITY_ID
FA0012687
FACILITY_NAME
CHEVRON PRODUCTS CO
STREET_NUMBER
2795
Direction
S
STREET_NAME
MACARTHUR
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
24614013
CURRENT_STATUS
01
SITE_LOCATION
2795 S MACARTHUR RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project No. JB-20100 <br /> 4 December 2000 <br /> Page 3 <br /> A resistance value (R-Value) test was performed on a representative bulk <br /> sample of the probable pavement subgrade soils. The R-Value test was <br /> performed according to California Department of Transportation (Caltrans) <br /> test methods. The test result was an R-Value of 18. <br /> 3.0 SUBSURFACE CONDITIONS <br /> 3.1 Surface <br /> At the time of our field exploration, the subject site was observed to be an <br /> open lot as shown in Figures 9 and 10, Photographs of Project Site. The <br /> subject property is approximately 225 feet wide and175 feet long. The site <br /> is currently an open lot covered with seasonal grasses. The site is relatively <br /> flat and appears to drain to the streets. Some ponding may occur on the <br /> site. <br /> 3.2 Subsurface <br /> • Fill was not encountered in the borings at the time of our field exploration. <br /> There may be fill in areas beyond or between our exploratory borings. <br /> In general, the native soils consisted of loose to medium dense sandy silt <br /> overlying very dense gravelly sand at a depth of about 24 feet. Observations <br /> indicate that the near surface soils have a low expansion potential. <br /> Groundwater was not encountered at the time of backfilling the borings. We <br /> expect groundwater levels to fluctuate due to variations in rainfall, <br /> groundwater recharge, and site conditions. <br /> 3.3 Seismic and Liquefaction Considerations <br /> Geologic references indicate that no fault trace designated active or <br /> potentially active passes through the subject property. The nearest active <br /> fault (Jennings, 1994) is the Greenville Fault. The Greenville Fault is <br /> approximately 12 miles from the site. The maximum moment magnitude for <br /> the Greenville Fault (CDMG Open-File Report 96-08, 1996) is 6.9. The <br /> subject site is located in Zone 4 as defined by the Uniform Building Code <br /> (1997 edition) on Figure 16-3, Seismic Zone Map of the United States. Based <br /> on the soils encountered in the borings the most appropriate Soil Profile <br /> ! Type would be SE. <br /> 1 It is our opinion, based on the soil conditions encountered in the borings, <br /> that the site soils encountered have a low potential of soil liquefaction. <br /> �Ko rbmachar Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.