Laserfiche WebLink
Project No. JB-20100 <br /> 4 December 2000 <br /> Page 3 <br /> A resistance value (R-Value) test was performed on a representative bulk <br /> sample of the probable pavement subgrade soils. The R-Value test was <br /> performed according to California Department of Transportation (Caltrans) <br /> test methods. The test result was an R-Value of 18. <br /> 3.0 SUBSURFACE CONDITIONS <br /> 3.1 Surface <br /> At the time of our field exploration, the subject site was observed to be an <br /> open lot as shown in Figures 9 and 10, Photographs of Project Site. The <br /> subject property is approximately 225 feet wide and175 feet long. The site <br /> is currently an open lot covered with seasonal grasses. The site is relatively <br /> flat and appears to drain to the streets. Some ponding may occur on the <br /> site. <br /> 3.2 Subsurface <br /> • Fill was not encountered in the borings at the time of our field exploration. <br /> There may be fill in areas beyond or between our exploratory borings. <br /> In general, the native soils consisted of loose to medium dense sandy silt <br /> overlying very dense gravelly sand at a depth of about 24 feet. Observations <br /> indicate that the near surface soils have a low expansion potential. <br /> Groundwater was not encountered at the time of backfilling the borings. We <br /> expect groundwater levels to fluctuate due to variations in rainfall, <br /> groundwater recharge, and site conditions. <br /> 3.3 Seismic and Liquefaction Considerations <br /> Geologic references indicate that no fault trace designated active or <br /> potentially active passes through the subject property. The nearest active <br /> fault (Jennings, 1994) is the Greenville Fault. The Greenville Fault is <br /> approximately 12 miles from the site. The maximum moment magnitude for <br /> the Greenville Fault (CDMG Open-File Report 96-08, 1996) is 6.9. The <br /> subject site is located in Zone 4 as defined by the Uniform Building Code <br /> (1997 edition) on Figure 16-3, Seismic Zone Map of the United States. Based <br /> on the soils encountered in the borings the most appropriate Soil Profile <br /> ! Type would be SE. <br /> 1 It is our opinion, based on the soil conditions encountered in the borings, <br /> that the site soils encountered have a low potential of soil liquefaction. <br /> �Ko rbmachar Engineering, Inc. <br />