My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_3Q13 QSSR QRSR QMR
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
1444
>
2900 - Site Mitigation Program
>
PR0527031
>
ARCHIVED REPORTS_3Q13 QSSR QRSR QMR
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2020 1:52:18 PM
Creation date
3/4/2020 11:55:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
3Q13 QSSR QRSR QMR
RECORD_ID
PR0527031
PE
2957
FACILITY_ID
FA0018318
FACILITY_NAME
FORMER COLUMBO / TOSCANA BAKERY
STREET_NUMBER
1444
Direction
S
STREET_NAME
LINCOLN
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16503005
CURRENT_STATUS
01
SITE_LOCATION
1444 S LINCOLN ST
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
946
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr.Thomas Bouhs .2- 16 March 2005 <br /> Ms.Kitty Walker <br /> proposed soil vapor monitoring points with an identifier that has not already been used <br /> for sample identification. <br /> 4. We do not concur with the monitoring schedule provided on Page 8 of the Work Plan. <br /> The scheduled monitoring does not propose sampling until six months after the startup of <br /> the SVE system and proposes to eliminate a sampling point after one round of non- <br /> detectable results. This is not sufficient. Increased monitoring is needed for the first <br /> three months of operation. After the initial rounds of sampling from the soil vapor <br /> monitoring points, the L&M OYI may propose performance based monitoring or a set <br /> time schedule. <br /> 5. The Work Plan needs to include monitoring for methane and polynuclear aromatic <br /> hydrocarbons. _ <br /> G. The L&M OU needs to provide a discussion of the.proposed teak test during sample <br /> collection, which is mentioned on page 8. <br /> 7, The locations of the five proposed soil vapor monitoring points are not sufficient to <br /> determine the radius of influence for the SVE system. At least one soil vapor monitoring <br /> point is needed to the west of the furthest SVE well to determine lateral radius of <br /> influence. A soil vapor monitoring point also is needed south of the screened portion of <br /> "ASVEā¢6." Furthermore,all of the monitoring points are proposed to a total depth of five <br /> feet below ground surface. Based on the depth of the SVE wells,about nine feet below <br /> ground surface, the L&M OU needs at least one location with multiple depth monitoring <br /> points to evaluate the effectiveness of the system at capturing vapors at and below the <br /> depth of the SVE well_ <br /> 8. Proposed SV-1 appears to be lncated to evaluate the influence from SVE-1,which is not <br /> consistent with the remaining four proposed soil vapor monitoring points,which are <br /> evaluating the"ASVE"wells, The L&M OU needs to include a discussion of each of the <br /> proposed soil vapor monitoring points with the rationale for their locations. <br /> 9. As shown on Figure 3 of the Work Plan,there is a large area between the dual phase <br /> extraction system west to the screened areas of ASVE-3 and ASVE-4. The L&M OU <br /> needs to discuss how it wi it determine the effects of the SVE system in this area. <br /> 10. Regional Board staff concurs with moving proposed soil vapor monitoring points under <br /> the apartment buildings,as requested in DTSC's attached memorandum, to accommodate <br /> data needs for the completion of a human health risk assessment. <br /> 11. Regional Board staff does not concur with drilling soil vapor monitoring point borings <br /> deeper than the proposed total depth of the proposed soil vapor monitoring point to <br /> collect additional data for the human health risk assessment, as commented on in the <br /> attached DTSC memorandum. For the data needed from deeper depths,the L&M OU <br />