Laserfiche WebLink
Stantec Consulting Services Inc. <br /> WATER SAMPLE FIELD DATA SHEET <br /> PROJECT M 211602384.600.9401 PURGED BY: -E F ,,,. WELL I.D.: rvl t..,r . I(_. <br /> SAMPLED BY: -..� 4' „ SAMPLE I.D.: <br /> CLIENT/LOCATION: Parcel 2A, W. Weber at N.Lincoln, Stockton, CA QA SAMPLES: <br /> DATE PURGED 7 - 17- 1 3 START(2400hr) 1330 END(2400hr) 13f5- <br /> DATE SAMPLED 1 7- 13 SAMPLE TIME(2400hr) P 3 SJ <br /> SAMPLE TYPE: Groundwater sp Surface Water Treatment Effluent Other <br /> CASING DIAMETER: 2" y® 3" 4" 5" 6" 8" Other <br /> Casing Volume:(gallons per foot) (0.17) (0.38) (0.67) (1.02) (1.50) (2.60) ( ) <br /> DEPTH TO BOTTOM(feet) CASING VOLUME(gal)= fp, f <br /> DEPTH TO WATER(feet)= CALCULATED PURGE(gal) <br /> WATER COLUMN HEIGHT(feet) ACTUAL PURGE(gal) <br /> FIELD MEASUREMENTS <br /> DATE TIME VOLUME TEMP. CONDUCTIVITY pH COLOR TURBIDITY <br /> (2400hr) (gal) (degrees F) (umhos/cm) (units) (visual) (NTU) <br /> 7-1?--r3 /335 (.• f 7,le G ccv Nr e_ <br /> 2, tleGlrt,r N. x <br /> i <br /> SAMPLE INFORMATION <br /> SAMPLE DEPTH TO WATER: /6, 7�' SAMPLE TURBIDITY: <br /> 80%RECHARGE: _,,,�2YES_NO ANALYSES: TPHg/BTWMtBE/TBA;TPHd/TPHo <br /> ODOR: p$ SAMPLE VESSEL PRESERVATIVE: 3x 40 ml VOA/HCL;3 x 40 ml VOA/HCL <br /> PURGING EQUIPMENT SAMPLING EQUIPMENT <br /> _Bladder Pump _Bailer(Teflon) _Bladder Pump Bailer(Teflon) <br /> Centrifugal Pump Bailer(PVC) _Centrifugal Pump Bailer ( PVC oridisposable) <br /> ,40 Submersible Pump _Bailer(Stainless Steel) _Submersible Pump —Bailer(Stainless Steel) <br /> _Peristalic Pump _Dedicated _Peristalic Pump _Dedicated <br /> Other: Other: <br /> Pump Depth: <br /> WELL INTEGRITY: . LOCKM <br /> REMARKS: <br /> }) <br /> SIGNATURE: Page of <br />