f r. International.Incorporated <br /> March 9, 1998 <br /> Mr. Ron Rowe <br /> San Joaquin County Public Health Services Environmental Health Division <br /> Site Mitigation Unit <br /> 304 Weber Street,Third Floor <br /> Stockton,CA 95202 <br /> RESULTS OF CONE PENETROMETER TESTING(CPT)SURVEY,FORMER SAN FRANCISCO <br /> FRENCH BREAD COMPANY FACILITY, 1444 SOUTH LINCOLN STREET, STOCKTON, <br /> CALIFORNIA,FOR METZ BAKING COMPANY <br /> Dear Mr. Rowe: <br /> On behalf of Metz Baking Company(Metz),SECOR.International Incorporated(SECOR)is pleased to submit <br /> this document which presents the results of a recently completed cone penetrometer testing(CPT) survey at <br /> 1444 South Lincoln Street in Stockton, California(the Site, see Figure 1.). The CPT survey was performed <br /> in general accordance with the work scrape proposed in SECOR's Work Plan dated November 24, 1997 and <br /> approved by San Joaquin County Environmental Health Division(SJCEHD)in a letter dated December 12, <br /> 1997. <br /> CPT SURVEY <br /> Objective and Technical Approach <br /> The results of prior Site investigations revealed the presence of petroleum hydrocarbon-affected soil and <br /> groundwater beneath the Site to a minimum depth of 85 feet below ground surface(bgs). Based on.the depth <br /> of investigation required to further assess the vertical and lateral extent of petroleum hydrocarbon-affected <br /> groundwater underlying the Site, SECOR recommended performing a CPT survey. A CPT rig provides a <br /> rapid,reliable, and economical means of determining stratigraphy,hydrogeologic characteristics (hydrostatic <br /> head and relative permeability)and collecting multiple depth discrete soil and/or groundwater samples without <br /> generating waste cuttings. <br /> Pre-Field Activities <br /> Before initiation of field activities,SECOR updated the existing Site-specific Health and Safety Plan(RASP) <br /> to address the proposed scope of work and obtained well construction permits from the SJCEHD. The <br /> proposed CPT locations were cleared with respect to underground utilities and other obstructions using a <br /> professional utility locator and Underground Service Alert(USA)was notified 48-hours in advance of field <br /> activities. <br /> Field Activities <br /> 1 A total of three CPT soundings were advanced at the Site between December 29 and 30, 1997. cluster at the <br /> locations shown on Figure 2. Three CPT locations proposed in SECOR's November 24, 1997 Work Plan <br /> were not advanced for the following reasons: 1)the two proposed CPT soundings located within the building <br /> were not advanced because the size of the CPT rig prohibited it from entering the building;and 2)the proposed <br /> . % CPT sounding located on the southern edge of the Site between the on-Site building and property line was not <br /> advanced due to presence of multiple hand dug holes which the CPT rig could not safely negotiate. <br /> H:ISFFBISTOCKTONNCPTSURV2.RPT SECOR International Incorporated <br /> 90 New Montgomery Street, Suite 620, San Francisco, CA 94105-4503 (415)882-1548 (415)882-4406 FAX www.secor.com <br />