Laserfiche WebLink
1 <br /> page 2 Project No 97-125 <br /> 15 March 1997 <br /> 1 ' <br />' TABLE 1 <br /> SUMMARY OF HYDRAULIC CONDUCTIVITY TESTING <br /> Interstate Brands Corp. <br />' EMCON Project No. 22605-101.01 <br /> Sample Description Ave Conte' Before-test Aker-test Hydraulic <br /> D Gradient idation Conductivity <br /> pros Oenarty Moisture GensrW Moisture {crnlsecl• <br /> IPsil 1pd1 196} (pof) {961 <br />' S-11-82 Brown clayey SAND 3-7 2 982 228 990 275 4 8E-6 <br /> with gravel <br />' ' Test performed In accordance with ASTM D5084-90 <br />