Laserfiche WebLink
Creolo icalTechxicslxt. <br /> B Page 6 <br /> Additional Site Characterization <br /> &4`h Quarter Groundwater Monitoring <br /> Project No. 1030.2 <br /> February 20,2004 <br /> Two groundwater samples from each borehole were submitted to the laboratory for analysis. <br /> A summary of the groundwater analytical data from the soil boring investigation is included <br /> as Table 4 while the laboratory data is included in Appendix B. <br /> 2.3.2 Soil Laboratory Analyses <br /> The following summarizes the soil sample testing used for this phase of work. The soil <br /> ' samples collected on November 12, 2003, were delivered to Sherwood Labs (California <br /> ELAP No. 1400), of Hilmar, California, for the following analyses: <br /> ' • Benzene, toluene, ethylbenzene and xylene (BTEX)by EPA method 8020 <br /> • Gasoline range petroleum hydrocarbons (TPH-Gasoline) by EPA method 8015(m) <br /> • MTBE by EPA method 8020 (positive results confirmed by EPA method 8260) <br /> The detection limits for these compounds are listed in the laboratory data sheets included in <br /> Appendix B and summarized in Table 3 of Appendix A. A Chain of Custody was <br /> ' completed for all samples collected and tracked to ensure sample integrity. <br /> As required under AB2886, the depth to groundwater data was submitted electronically to <br /> ' GeoTracker on January 7, 2004, and the confinnation number is 6530377566. <br /> 2.3.3 Groundwater Laboratory Analyses <br /> The following summarizes the groundwater sample testing used for the soil boring <br /> investigation. The groundwater samples collected on November 12, 2003, were delivered to <br /> Sherwood Labs (California ELAP No. 1400), of Hilmar, California, for the following <br /> analyses: <br /> ' • Benzene, toluene, ethylbenzene and xylene (BTEX)by EPA method 8020 <br /> • Gasoline range petroleum hydrocarbons (TPH-Gasoline) by EPA method 8015(m) <br /> ' • MTBE by EPA method 8020 (positive results confirmed by EPA method 8260) <br /> The detection limits for these compounds are listed in the laboratory data sheets included in <br /> ' Appendix B and summarized in Table 4 of Appendix A. A Chain of Custody was <br /> completed for all samples collected and tracked to ensure sample integrity. <br /> ' As required under AB2886, the depth to groundwater data was submitted electronically to <br /> GeoTracker on January 7, 2004, and the confirmation number is 6530377566. <br /> 2.4 Quarterly Groundwater Monitoring <br /> ' 2.4.1 Groundwater Sampling Procedure <br /> On October 16, 2003, Del-Tech Geotechnical Support Service (Del-Tech) personnel arrived <br /> ' on-site, opened the wells and measured the depth to water with an electrically actuated <br /> sounding tape. The water level reading was recorded to an accuracy of 0.01 foot. 1f free - <br /> floating product had been suspected, a clear disposable bailer would have been used to <br /> gauge the interface. No floating product was observed during this sampling event. <br /> ' Stagnant water in the well casing was purged using a Waterra pump and dedicated tubing. <br /> g <br /> The rate of well purging was monitored. The well was purged of at least three casing <br />