My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0013093
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
100
>
2900 - Site Mitigation Program
>
PR0545430
>
ARCHIVED REPORTS_XR0013093
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2020 9:44:25 AM
Creation date
3/5/2020 9:16:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0013093
RECORD_ID
PR0545430
PE
2950
FACILITY_ID
FA0000157
FACILITY_NAME
JACK IN THE BOX #588
STREET_NUMBER
100
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19821016
CURRENT_STATUS
02
SITE_LOCATION
100 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ckn KLEINFELDER <br /> APPENDIX A <br /> KLEINFELDER FIELD PROTOCOL <br /> A-1 FIELD PREPARATION i <br /> Before performing work in the field, <br /> environmental staff review the scope of work, prepare <br /> y a health and safety plan, coordinate the work to be done with their supervisor, assemble <br /> the necessary sample containers, and check, calibrate and clean equipment to be used in <br /> the field. When underground utilities may exist at a site where subsurface soil samples are <br /> being collected, USA Underground is contacted with the boring locations and the ; <br /> scheduled date of drilling, or a utility locating firm is employed to check! the boring <br /> locations. <br /> A-2 SUBSURFACE SOIL SAMPLING <br /> A-2.1 Drilling <br /> Subsurface soil samples are collected from soil borings. Soil borings are advanced using a <br /> truck-mounted drill rig, equipped with 8-inch hollow stem augers. The borings can be <br /> advanced vertically, or at an angle up to 45 degrees from vertical. During; drilling, an <br /> experienced environmental geologist classifies the soil, logs the lithology and collects soil <br /> samples for laboratory analysis. A sample boring log form is attached at the end of this <br /> appendix. <br /> A-2.2 Decontamination of Equipment <br /> To reduce the potential for cross-contamination, augers and associated equipment are <br /> steam cleaned prior to drilling each boring. In addition, sampling equipment is cleaned <br /> with a trisodium phosphate wash and rinsed with distilled water prior to collecting each soil <br /> sample. ' <br /> i <br /> FR25-91-22 Page A-I <br /> Copyright 1991 Kleinfelder,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.