Laserfiche WebLink
September 07, 2006 Lab ID : STK636936 <br /> Alpine Packing Company Customer : 3-2839 <br /> Quality Control - Inorganic <br /> tituent Method Date/ID Type Units Conc. QC Data DQO Note <br /> «et' Chem <br /> Conductivi 251013 08/15/2006:A 00-ICV umbos/cm 10000 10196 95-105 <br /> 00-CCV umhos/cm 1006 101% 95-105 <br /> Nitrate + Nitrite as N 450ONO3F 08118/2006:13220 MS mg/L 4.000 69.2% 3-211 <br /> (SP 608221-01) MSD mg/L 4.000 . 71.1% 3-211 <br /> MSRPD mg/L 2.5% 535.0 <br /> 08/22/2006:A220 MS mg/L 4.000 62.3% 3-211 <br /> (SP 608331-02) MSD mg/L 4.000 60.4% 3-211 <br /> MSRPD mg/L -3.1% 535.0 <br /> 450ONO3F 08/21/2006:8 01-CCB mg/L ND <0.1 <br /> 01-CCV mg/L 4.000 108% 90-110 <br /> 02-CCB mg/L ND <0.1 <br /> 02-CCV mg/L 4.000 106% 90-110 <br /> 08/23/2006:A 00-ICB mg/L ND <0.1 <br /> 00-ICV mg/L 4.000 98.0% 90-110 <br /> 01-CCB mg/L ND- <0.1 <br /> 01-CCV mg/L 4.000 97.4% 90-110 <br /> pH 4500-H B 08/11/2006:5346 Dup units 0.0% 4.80 <br /> 4500-H B 08/11/2006:5 00-CCV units 8.000 100% 95-105 <br /> Solids. Total Dissolved (TDS) 2540C 08/15/2006:A235 Blank mg/L ND <40 <br /> LCS mg/L 1000 98.3% 90-110 <br /> Dup mg/L 0.9% 10.0 <br /> Explanations <br /> 408 Matrix Spike(MS) or Post Digestion Spike(PDS) has no Acceptance Range (DQO) because of high analyte <br /> concentration in the sample. Data was accepted based on the LCS or CCV recovery. <br /> 435 Sample matrix may be affecting this analyte. Data was accepted based on the LCS or CCV recovery. <br /> Definitions <br /> Blank Method Blank - Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> LCS Laboratory Control Standard,'Sample - Prepared to verify that the preparation process is not affecting analyte <br /> recovery. <br /> MS/MSD Matrix Spikes - A random sample is spiked with a known amount of analyte. The recoveries are an indication o <br /> how that sample matrix affects analyte recovery. <br /> Dup Duplicate Sample - A random sample with each batch is prepared and analyzed in duplicate. The relative percent <br /> difference is an indication of precision for the preparation and analysis. <br /> - ICB Initial Calibration Blank - Analyzed to verify the instrument baseline is within criteria. <br /> ICV Initial Calibration Verification - Analyzed to verify the instrument calibration is within criteria. <br /> CCB Continuing Calibration Blank - Analyzed to verify the instrument baseline is within criteria. <br /> CCV Continuing Calibration Verification - Analyzed to verify the instrument calibration is within criteria. <br /> ND Non-detect - Result was below the DQO listed for the analyte. <br /> <'k High Sample Background - Spike concentration was less than one forth of the sample concentration. <br /> DQO Data Quality Objective - This is the criteria against which the quality control data is compared. <br /> Report continued on next page... <br /> STK636936: Quality Control Page 2 <br />