My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1521
>
2200 - Hazardous Waste Program
>
PR0507077
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2020 1:03:32 PM
Creation date
3/5/2020 10:17:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0507077
PE
2229
FACILITY_ID
FA0005303
FACILITY_NAME
HOLT OF CALIFORNIA
STREET_NUMBER
1521
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337015
CURRENT_STATUS
01
SITE_LOCATION
1521 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
486
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�= "CEIVEC <br />AUG 2 4 2015 <br />ENVIRONMENTAL <br />amec 1p <br />jJCQ%TU nCOAPTRAMIT <br />foster <br />wheeler <br />Seismic/Anchoring: <br />Seismic/dynamic/hydrostatic load calculations provided with "Hydrostatic <br />and Seismic Analysis" page or as Attachment 3. <br />Seismic/Anchoring findings: The tank as designed and operated, and the <br />containment area in which it is located are adequately anchored and meet <br />minimum seismic safety standards. Initials: S¢4 <br />Leak Test: <br />Brief description of leak test, including type of test used, and results of <br />test: This tank was integrity tested based on recommendations from the <br />manufacturer and the Steel Tank Institute's Standard SP001, "Standard for the <br />Inspection of Aboveground Storage Tanks" (STI SP001). This standard provides <br />recommended integrity testing schedules based on risk to the environment, <br />considering factors such as spill control, release detection methods, and storage <br />capacity. Table 5.5, "Table of Inspection Schedules", of STI SP001 recommends <br />tanks of this size and type undergo periodic visual, documented inspections to <br />assess general AST conditions. These inspections may be conducted by the <br />AST owner and without suspending AST operations or removing the AST from <br />service. Holt of CA conducts these types of inspections on a daily basis. The <br />tank inspector reviewed Holt of CA inspection logs and conducted his own <br />assessment based on the attached checklist. The tank was deemed to be in <br />proper working order and the integrity sound. A detailed description of the <br />integrity testing standard used as well as sample inspection logs are located in <br />Attachment 2. <br />Integrity testing findings: Based on the above noted integrity test and the <br />results obtained from that test, the tank has sufficient integrity for its intended <br />use. Initials: 7-59 <br />Amec Foster Wheeler Environment & Infrastructure, Inc. 1,000 Gal. Waste Oil Tank <br />
The URL can be used to link to this page
Your browser does not support the video tag.