Nov-02-99 02:09P COPPEF.L._EN-rERPRI5E5 1 209 727 9773 P_02 <br /> I k <br /> k <br /> 4 <br /> Aeration Plan <br /> 500 Gallon Gasoline UST <br /> Former Lockeford Winery <br /> Lockeford, California �II <br /> 1 <br /> 1.0 Background <br /> On August 20, 1999 a 500 gallon underground storage tank was removed and <br /> transported off-site for disposal. The UST was a single wall steel tank and <br /> formerly contained gasoline. The UST was last used in the late 1980'$. After <br /> .removal, a backhoe was used to collect a soil sample at a depth of two feet <br /> below the invert of the UST (approximately 8 feet below ground surface). A four- <br /> in-one composite sample was also collected from the soil stockpile. The sample <br /> taken from below the UST contained 690 ppm TPH gasoline. Please see <br /> Sample Result Summary. <br /> The planned future activities at the site include over-excavation of the UST <br /> excavation to remove any remaining contaminated soil from the excavation. The <br /> excavated soil will be placed in a temporary soil stockpile. <br /> 2.0 Aeration Pad <br /> The proposed aeration pad will be the existing concrete slab located adjacent to <br /> the north side of the UST excavation. The slab is of sufficient size to <br /> accommodate the contaminated soil from the UST excavation. Prior to <br /> placement of soil on the slab, any debris will be removed from the slab and the <br /> concrete will be swept clean. <br /> The soil will then be removed from the soil stockpile and spread out on the <br /> concrete slab. The soil will be placed at a maximum depth of one (1) foot. <br /> 1 of 2 <br />