F04THILL; ... <br /> • ..``" - �-� � `'k.:,.`� l"�E ENGINEERING <br /> 12793 PADDY CREEK LANE LODI, CA 95240 <br /> JUI 5., Ali 11, 23 PH. (209) 368.-9387 FAX(204) 367-1163 <br /> Ms. Margaret Lagorio June 3, 1997 <br /> San Joaquin County Public Health Services <br />{ Environmental Health Division <br /> P. O. Box 388 <br /> Stockton, CA 95201 <br />! Subject: Payless Building Supplies- Gasoline Tank Removed Site code: 500140 <br /> Dear Ms. Lagorio, <br /> t <br /> John GrafPxgna, owner of the above stated property, has asked Foothill Engineering to proceed with <br /> an investigation of the area surrounding the removed underground gasoline storage-tank. Original <br /> ` analysis of the soil below the storage tank indicated that some gasoline contamination'lay be present. <br /> SITE HISTORY <br /> The subject gasoline tank was removed in July of 1993 by Thorpe Oil of Lodi, California. A soil <br /> sample taken from the area under the center of the*IC at a depth of 8:5 feet below the surface was <br /> analyzed and found to 'contain elements of BTEX and gasoline (see attached report,J from <br /> GeoAnalytical Laboratories dated 07120/93).` <br /> The following is a proposed'work plan.for the site investigation. <br /> THE SITE INVESTIGATION WORK PLAN <br /> 1 We propose to place a soil boring at or near the center of the excavation.of the removed underground <br /> storage tank. Soil samples will be taken at ten foot intervals by a split spoon sampler from a hollow <br /> stem auger.Each sampCe will bb'logged'for-soil classification and-marked for iuentificaticn.: <br /> Each soil tube will be capped with a layer'of aluminum foil secured by plastic caps, sealed with duct_ <br /> tape, labeled for identification, and stored on ice for transport to the laboratory. Soil samples will be <br /> transported under a chain of custody to Sherwood Labs of Hilmar, Ca.-for analysis: Samples will be <br /> analyzed per EPA Methods 8020 (BTEX), (MTBE), 5030/8015(M) TPH-Gasoline and 7420 for <br /> lead.. <br /> If the soil samples or site conditions indicate that the contamination is at or near the existing water <br /> table, a 2" PVC monitoring well will be installed (see attached detail for well construction). The <br /> monitoring well will be purged and sampled as per standard practices_of the,industry. Water samples <br /> will be analyzed for BTEX, TPH-Gasoline, and lead. <br /> A report of all findings will be directed to the San Joaquin County Public Health- Services <br /> Environmental Health Division and the site owner <br /> r <br /> 1 <br /> i <br />