CAMBRIA <br /> Table 1: Soil Vapor Extraction Field Test - Summary - Shell-branded Service Station, <br /> Incident#98995874, 341 East Main Street,Ripon,California <br /> Extracted Well Va or <br /> Well Time Vacuum Conc. Flow Notes <br /> ("WC) <br /> (PPM) (cfm) <br /> EW-1 9:40 AM - - - Start test on EW-1 <br /> 10:30 AM 16 0.0 33 <br /> 10:40 AM 27 0.0 52 <br /> 10:50 AM 33 0.0 68 <br /> 1 t:10 AM 39 0.0 75 <br /> 11:20 AM 35 0.0 77 <br /> l 1:30 AM 34 0.0 78 <br /> 12:00 PM 33 0.0 56 <br /> 12:20 PM 36 0.0 57 <br /> 12:30 PM 34 0.0 58 <br /> 12:45 PM 36 0.0 58 <br /> 1:00 PM - - - Stop test at 1:00 PM <br /> MW-4B 1:15 PM - - - Start test on MW-4B <br /> 1:30 PM 225 0.0 27 <br /> 1:45 PM 256 0.0 0 <br /> 2:00 PM 253 0.0 0 <br /> 2:15 PM 257 0.0 0 Stop test at 2:15 PM <br /> MW-1 2:30 PM - - - Start test on MW-1 <br /> 2:45 PM 14 0.0 41 <br /> 3:00 PM 15 0.0 44 <br /> 3:30 PM 14 3.0 46 Stop test at 3:30 PM <br /> Abbreviations&Notes: <br /> conc. =concentration <br /> "WC =inches of water column vacuum <br /> ppm =parts per million,as measured with FID <br /> cfm =cubic feet per minute,as measured with pitot tube and digital manometer <br /> G:/Ripon 341/Reports/SVB Test/SVE Rpt Tables.xls 1 of 1 Tbll-Test Summ <br />