Laserfiche WebLink
PRESENTATION OF CONE PENETRATION TEST DATA <br /> 1.0 INTRODUCTION <br /> This report presents the results of a Cone Penetration Testing (CPT) program carried out <br /> at the Shell Station located in Ripon, CA The work was performed on February 24 through <br /> February 26, 1999 The scope of work was performed as directed by Cambna personnel <br /> Q <br /> 2.0 FIELD EQUIPMENT & PROCEDURES <br /> The Cone Penetration Tests (CPT) were camed out by GREGG IN SITU, INC of Martinez, <br /> CA using an integrated electronic cone system The CPT soundings were performed in <br /> accordance with ASTM standards (D3441) A 20 ton capacity cone was used for all of the <br /> soundings This cone has a tip area of 15 sq cm and friction sleeve area of 225 sq cm <br /> The cone is designed with an equal end area friction sleeve and a tip end area ratio of <br /> 085 <br /> The cones used during the program recorded the following parameters at 5 cm depth <br /> intervals <br /> - Tip Resistance (Qc) <br /> - Sleeve Friction (Fs) <br />' - Dynamic Pore Pressure (Ut) <br /> The above parameters were printed simultaneously on a printer and stored on a computer <br /> diskette for future analysis and reference <br /> The pore water pressure element was located directly behind the cone tip The pore water <br /> pressure element was 5 0 mm thick and consisted of porous plastic Each of the elements <br /> were saturated in glycerin under vacuum pressure prior to penetration Pore pressure <br />' dissipations were recorded at 5 second intervals when appropriate during pauses in the <br /> penetration <br />' A complete set of baseline readings was taken prior to each sounding to determine <br /> temperature shifts and any zero load offsets Monitoring base line readings ensures that <br />' the cone electronics are operating properly <br /> The cones were pushed using GREGG's truck-mounted CPT rig, having a down pressure <br /> capacity of approximately 25 tons Five (5) CPT soundings were performed The <br /> 1 penetration tests were carried to depths of approximately 60 to 70 feet below ground <br /> surface Test locations and depths were determined in the field by Cambria personnel <br /> 1 <br />