Laserfiche WebLink
� AMBRIA <br /> 1996 Tank Replacement: In August 1996, three gasoline underground storage tanks (located in <br /> the northwest corner of the site), four product dispensers, and associated piping were removed <br /> and replaced with two fiberglass gasoline storage tanks(in the northeast portion of the site), new <br /> product dispensers, and new fiberglass piping Cambria collected soil samples during the <br /> replacement of the USTs,dispenser islands,and product lines at the site <br /> The maximum TPHg concentration detected in soil samples collected from the former tank pit <br /> was 1,300 parts per million (ppm) total petroleum hydrocarbons as gasoline (TPHg) in a sample <br /> collected from 13 feet below grade (fbg) beneath the east end of the northernmost UST This <br /> area was over-excavated to a depth of 25 fbg, and a subsequent sample collected at that depth - <br /> contained less than 5 ppm of TPHg The maximum benzene and MTBE concentrations detected <br /> in soil samples collected beneath the former tank pit were 0 055 ppm and 12 ppm,respectively <br /> 2 <br /> TPHg was detected in only one soil sample collected beneath the dispensers at the site at a <br /> concentration of 1,200 ppm The area was subsequently over-excavated to approximately 9 fbg, <br /> and no TPHg was detected in a soil sample collected at this depth No benzene was detected in <br /> soil samples collected froiabenerh the dispenser islands at the site MTBE was detected in one <br /> I 4-. soil sample collected fron�F eneath the dispensers at a concentration of 0 22 ppm. This area was <br /> also over-excavated to approximately 9 fbg, and no MTBE was detected in the soil sample <br /> collected at this depth <br /> TPHg and benzene were detected in one soil sample collected beneath the piping and vent lines <br /> at the site at concentrations of 3 1 ppm and 0 028 ppm, respectively MTBE was detected in two <br /> soil samples collected beneath the piping and vent lines with a maximum concentration of <br /> 34 ppm The sampling, excavation, and analytical results are documented in Cambria's <br /> July 16, 1997 Underground Storage Tank Removal and Soil Sampling Report <br /> 1997 Horst Removal. In September 1997, three hydraulic hoists were replaced at the site, and <br /> Cambria collected soil samples beneath the hoists No total petroleum hydrocarbons as hydraulic <br /> oil or benzene was detected in the soil samples collected Hoist removal sampling results are <br /> documented in Cambria's October 17, 1997 Hoist Replacement Sampling Report .I- <br /> 1998 Groundwater Monitoring Well Installation- In March 1998, Cambria installed three <br /> groundwater monitoring wells (MW-1 through MW-3) at the site (Figure 2) Up to 19 ppm <br /> TPHg was detected in soil samples collected from well MW-1, located adjacent to the former <br /> USTs in the northwest corner of the site No TPHg or benzene was detected in any other soil — <br /> 0323 2 <br />