1' <br /> Geologunl?eckracs Inc Page 3 <br /> Groundwater Monitoring Report <br /> Project No 770 2 <br /> November I3,2001 <br /> r <br /> For the September 19, 2001, monitoring event, a vertical gradient was calculated for the <br /> MW-5/MW-105 pair The vertical gradient was negative (a downward direction) and <br /> ' approximately 24 times greater magnitude (0 024) than the horizontal gradient of shallow <br /> wells MW-1 through MW-3 (0 001) The vertical gradients calculated for previous events <br /> ' are negative on August 28, 2000, and positive on December 29, 2000 and March 15, 2001 <br /> Similar to the historical lateral directions, the movement of groundwater in the vertical <br /> plane also fluctuates at the site <br /> ' 1.2 Groundwater Sampling Procedure <br /> ' On September 19, 2001 Don Light of Del-Tech mobilized to the site to conduct <br /> groundwater monitoring of the seven monitoring wells <br /> ' Before sampling was attempted the wells were sounded for depth to water and then a clear <br /> disposable bailer was used to determine if floating product was present The wells were <br /> purged of at least three well volumes of stagnant water using a dedicated Waterra check-ball <br /> ' assembly and % inch tubing Purging continued until the temperature, conductivity, and pH <br /> of the groundwater stabilized (<10% variation between three readings) indicating that <br /> formation water representative of aquifer conditions was entering the wells These water <br /> quality parameters were measured at intervals of each well volume purged <br /> Once purging was complete, a water sample was collected from the Waterra tube Care was <br /> ' taken to minimize sample agitation Once the sample container was filled and capped, the <br /> bottle was inverted, tapped, and checked for headspace bubbles The sample container was <br /> identified and labeled with a unique designation, inserted into foam holders and placed in an <br /> ice chest cooled to 4°C for transport to the laboratory <br /> ' All non-disposable sampling equipment was decontaminated using a hot water washer and <br /> detergent before and between uses Disposable gloves were used by the technician to <br /> collect all samples and were changed with each sample collection <br /> A chain of custody document, listing all samples collected, accompanied the samples from <br /> field to laboratory, thereby providing a means to track their movement and insure their <br /> ' integrity <br /> All water purged from each monitoring well and not used as a sample, was placed in a 55 <br /> gallon DOT approved container, properly labeled and stored on site until its proper <br /> disposition can be arranged <br /> ' Groundwater monitoring field logs are included in Appendix C <br /> r <br /> 1 <br />