My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0013070
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOOMIS
>
2969
>
3500 - Local Oversight Program
>
PR0545428
>
ARCHIVED REPORTS_XR0013070
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/9/2020 7:00:15 PM
Creation date
3/9/2020 10:55:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0013070
RECORD_ID
PR0545428
PE
3528
FACILITY_ID
FA0005487
FACILITY_NAME
MARCIS DIESEL SERVICE
STREET_NUMBER
2969
STREET_NAME
LOOMIS
STREET_TYPE
RD
City
STOCKTON
Zip
95205
CURRENT_STATUS
02
SITE_LOCATION
2969 LOOMIS RD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r Wrn. J. Hunter & Associates 2220 Loma vista Dr. <br /> Registered Geologists €:; `III,4, .;' { ;1 ;`hj ';{ Sacramento, CA 95825 <br /> Petroleum & Mineral Appraisers - '?'i`�" {916) 972-7941 <br /> I `j , 7�L FAX (916) 972-1683' <br /> November 5, 1996 <br /> Linda Turkatte, Sr. REHS - <br /> o- San Joaquin County PHS <br /> Environmental Health Division <br /> P. O. .Box 388 <br /> Stockton, CA 95201-0388 <br /> Ref : RESULTS OF GROUNDWATER SAMPLING - MARCI '-S DIESEL SERVICE, <br /> 2969 LOOMIS ROAD, STOCKTON <br /> On October 10, 1996, Del;-Tech Geotechnical Support Services- <br /> determined depth to water, and purged & sampled monitoring well <br /> #1 at the above site. Water levels were .also measured in MW-2 & <br /> ' MW-3, but per instructions from the EHD, those wells were not <br /> sampled. The field work� was witnessed by a representative of the <br /> San Joaquin EHD. A copy° of the field log, chain ,of custody <br /> forms, and laboratory analyses -of the water samples taken from <br /> MW--1 are included. <br /> The direction of groundwater flow is to the southwest as shown on <br /> EXHIBIT 'A. The. gradientis very low, at about . 0006 ' /ft . <br /> EXHIBIT'B shows the directions of flow since monitoring began. <br /> ;. <br /> Depth to groundwater during this event averaged 69 . 23 ' below # <br /> grade, the highest level since monitoring. began .in April, 1992 . <br /> ' There have been a total of 27water level measurements taken . <br /> since the start of the project . The maximum.variation in - <br /> elevation-was 4 . 801 , and`'- the- average depth to water is 71 .281 <br /> bgl . This small fluctuation in water levels,,' .coupled with the <br /> highly divergent gradient-,• strongly-suggests, a�-very- limited <br /> aquifer of- extremely low transmissivity. <br /> TABLE 1 summarizes=- all of the result's of water..analyses since <br /> monitoring began. Because MW-1' had riot been entered since <br /> November, 1994, a water sample was taken prior to purging the <br /> well . The ' well was then. purged`, and sampled as detailed in the <br /> attached field notes submitted by Del-Tech. The water sample <br /> taken prior to purging measure& 1:2 ug/L of xylene; ,benzene, <br /> toluene, ethylbenzene, MBTE, & TPHd were below detection levels . <br /> After purging the well, the- water sample measured 1..3 ug/L; all <br /> others were non-detect . ' The bailer blank prior to the second j <br /> sampling also revealed xylene at 1. 1 ug/L. The 'reason for this <br /> has not been identified. A new; disposable bailer_ was used to <br /> collect the sample prior. to purging, and also .for the bailer' <br /> blank. The second water' sample- was collected with a stainless <br /> steel bailer which had been thoroughly cleaned and rinsed prior <br /> to use . Although it is possible that the °very minor amount of <br /> i. xylene could have .been caused by contamination in the laboratory, <br /> 1 . <br />
The URL can be used to link to this page
Your browser does not support the video tag.