Laserfiche WebLink
.i <br /> LancasterLaboratories ' Abbreviations., <br /> 2425 New Holland Pike•Lancaster,PA 17607 Explanation of Symbols and I <br /> Y <br /> The following defines common symbols andabbreviations used in reporting technical data: <br /> N.D. none detected BMQL Below Minimum Quantitation Level o <br /> TNTC Too Numerous To Count i MPN Most Probable Number <br /> IU International Units CP Units cobalt-chloroplatinate units <br /> umhoslcm micromhos/cm NTU nephelometric turbidity units ) <br /> C degrees Celsius F degrees Fahrenheit j <br /> meq milliequivalents Ib. pound(s) <br /> g gram(s) kg kilogram(s) <br /> ug microgram(s) mg milligram(s) ? f <br /> ml milliliter(s) I liter(s) <br /> m3 cubic meter(s) ul microliter(s) I <br /> < less than-The number following the sign is the limit of quantitation,the smallest amount of analyte which can be <br /> reliably determined using this specific test. <br /> > greater than 1 <br /> J estimated value—The result is?the Method Detection Limit(MDL)and <the Limit of Quantitation (LOQ). <br /> � I f <br /> PPM parts per million-One ppm is equivalent to one milligram per kilogram(mg/kg), or one gram per million'grams. For <br /> aqueous liquids, ppm is usually taken to be equivalent to milligrams per liter(mg/1), because one liter of water has a <br /> weight very close to a kilogram. For gases or vapors, one ppm is equivalent to one microliter of gas per liter of gas. i <br /> ppb parts per billion l <br /> s. Dry weight Results printed under this heading have been adjusted for moisture content. This increases the analyte weight <br /> basis concentration to approximate the value present in a similar sample without moisture. All other results are reported <br /> on an as-received basis. i <br /> i <br /> U.S. EPR CLP Data Qualifiers. ; l , <br /> Organic Qualifiers ' Inorganic Qualifiers <br /> A TIC is a possible aldol-condensation product B Value is<CRDL, but>_IDL <br /> B Analyte was also detected in the blank E Estimated due to interference ' <br /> C Pesticide result confirmed by GC/MS M Duplicate injection precision not met 9 <br /> D Compound quantitated on a diluted sample N Spike sample not within control limits <br /> E Concentration exceeds the calibration range of S Method of standard additions (MSA) used { <br /> the instrument for calculation <br /> N Presumptive evidence of a compound (TICs only) U Compound was not detected <br /> P Concentration difference between,primary and W Post digestion spike out of control limits <br /> confirmation columns>25% i Duplicate analysis not within control limits i <br /> U Compound was not detected + Correlation coefficient for MSA<0.995 3 <br /> X,Y,Z Defined in case narrative I <br /> Analytical test results for methods listed on the laboratories' accreditation scope meet all requirements of NELAC unless <br /> otherwise noted under the individual analysis. q <br /> Measurement uncertainty values, as applicable, are available upon request. I F <br /> Tests results relate only to the sample tested. Clients should be aware that a critical step in a chemical or microbiological <br /> analysis is the collection of the sample. Unless the sample analyzed is truly representative of the bulk of material involved;the <br /> test results will be meaningless. If you have questions regarding the proper techniques of collecting samples, please contact <br /> us. We cannot be held responsible for sample integrity, however, unless sampling has been performed by a member of our <br /> staff. This report shall not be reproduced except?in full,without the written approval of the laboratory. <br /> WARRANTY AND LIMITS OF LIABILITY-In accepting analytical work, we warrant the accuracy of test results for the sample as submitted. i <br /> THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR <br /> j IMPLIED. WE DISCLAIM ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING A WARRANTY OF FITNESS FOR <br /> PARTICULAR PURPOSE AND WARRANTY OF MERCHANTABILITY. IN NO EVENT SHALL LANCASTER LABORATORIES BE LIABLE <br /> FOR INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS <br /> OF PROFIT OR GOODWILL REGARDLESS OF(A)THE NEGLIGENCE(EITHER SOLE OR CONCURRENT)OF LANCASTER I <br /> LABORATORIES AND(B)WHETHER LANCASTER LABORATORIES HAS BEEN INFORMED OF THE POSSIBILITY OF SUCH I <br /> I: _r)AMAGES. We accept no legal responsibility for the purposes for which the client uses the test results. No purchase order or other order <br /> -� it work shall be accepted by Lancaster Laboratories which includes any conditions that vary from the Standard Terms and Conditions of <br /> T.tancaster Laboratories and we hereby object to any conflicting terms contained in any acceptance or order submitted by client. <br /> 3768.02 <br />