+Lancaster Laboratories ' <br /> 2425Ex " lanai 'NewH°ua�dP�ke.��,�Sce�Pn,�so' p ton of Symbols and Abbreviations <br /> The following defines common symbols and abbreviations used in reporting technical data: k <br /> N.D. none detected BMQL Below Minimum Quantitation Level <br /> TNTC Too Numerous To Count MPN Most Probable Number <br /> IU International Units CP Units cobalt-chloroplatinate units <br /> umhostcm micromhos/cm NTU nephelometric turbidity units ! <br /> C degrees Celsius F degrees Fahrenheit <br /> meq milliequivalents Ib. pound(s) ' <br /> g gram(s) kg kilogram(s) <br /> ug microgram(s) mg milligram(s) <br /> ml milliliter(s) I liter(s) <br /> m3 cubic meter(s) UI microliter(s) <br /> r <br /> < less than-The number following the sign is the limit of quantitation,the smallest amount of analyte which can be <br /> reliably determined using this specific test. <br /> > greater than <br /> i <br /> J estimated value—The result is>_the Method Detection Limit(MDL) and <the Limit of Quantitation (LOQ). I <br /> ppm parts per million-One ppm is equivalent to one milligram per kilogram (mg/kg), or one gram per million grams. For <br /> aqueous liquids, ppm is usually taken to be equivalent to milligrams per liter(mg/1), because one liter of water las a <br /> weight very close to a kilogram. For gases or vapors, one ppm is equivalent to one microliter of gas per liter ofpas. <br /> ppb parts per billion 1 <br /> Dry weight Results printed under this heading have been adjusted for moisture content. This i'hcreases the analyte weight' <br /> basis concentration to approximate the value present in a similar sample without moisture. All other results are reported ' <br /> on an as-received basis. <br /> h <br /> U.S. EPA CLP Data Qualifiers: <br /> Organic Qualifiers ' Inorganic Qualifiers <br /> A TIC is a possible aldol-condensation product B Value is<CRDL, but>—IDL { <br /> f B Analyte was also detected in the blank E Estimated due to interference <br /> C Pesticide result confirmed by GC/MS M Duplicate injection precision not met <br /> D Compound quantitated on a diluted sample N Spike sample not within control limits <br /> E Concentration exceeds the calibration range of 5 Method of standard additions(MSA) used <br /> the instrument for calculation <br /> N Presumptive evidence of a compound (TICs only) U Compound was not detected <br /> F <br /> P Concentration difference betweeniprimary and W Post digestion spike out of control limits <br /> confirmation columns X25% Duplicate analysis not within control limits <br /> U Compound was not detected + Correlation coefficient for MSA<0.995 <br /> X,Y,Z Defined in case narrative <br /> Analytical test results for methods listed on the laboratories'accreditation scope meet all requirements of NELAC unless i <br /> otherwise noted under the individual analysis. <br /> Measurement uncertainty values, as applicable, are available upon request. <br /> Tests results relate only to the sample tested. Clients should be aware that a critical step in a chemical or microbiological <br /> analysis is the collection of the sample. Unless the sample analyzed is truly representative of the bulk of material involved;the <br /> test results will be meaningless. If you have questions regarding the proper techniques of collecting samples, please contact <br /> us. We cannot be held responsible for sample integrity, however, unless sampling has been performed by a member of o 6r <br /> staff. This report shall not be reproduced exceptin full, without the written approval of the laboratory. ; <br /> WARRANTY AND LIMITS OF LIABILITY-In accepting analytical work,we warrant the accuracy of test results for the sample as submitted. ` <br /> THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR <br /> IMPLIED. WE DISCLAIM ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING A WARRANTY OF FITNESS FOR I <br /> PARTICULAR PURPOSE AND WARRANTY OF MERCHANTABILITY. IN NO EVENT SHALL LANCASTER LABORATORIES BE LIABLE <br /> FOR INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS <br /> OF PROFIT OR GOODWILL REGARDLESS OF (A)THE NEGLIGENCE(EITHER SOLE OR CONCURRENT)OF LANCASTER <br /> LABORATORIES AND(B)WHETHER LANCASTER LABORATORIES HAS BEEN INFORMED OF THE POSSIBILITY OF SUCH # <br /> AMAGES. We accept no legal responsibility for the purposes for which the client uses the test results. No purchase order or other order <br /> r work shall be accepted by Lancaster Laboratories which includes any conditions that vary from the Standard Terms and Conditions.of <br /> Q]ncaster <br /> Laboratories and we hereby object to any conflicting terms contained in any acceptance or order submitted by client. <br /> 3768.02 j <br /> l <br /> I <br />