Laserfiche WebLink
Lancaster Laboratories <br /> Explanation of Symbol ' <br /> +2425 New Holldnd Pike a Lancasler,PA 17601 sand Abbreviations <br /> The following defines common symbols and abbreviations used in reporting technical data: <br /> N.D. none detected BMQL Below Minimum Quantitation Level <br /> TNTC Too Numerous'To Count MPN Most Probable Number <br /> IU Intemational Units CP Units cobalt-chloroplatinate units <br /> umhoslcm micromhos/cm i NTU nephelometric turbidity units I <br /> C degrees Celsius F degrees Fahrenheit k <br /> ;meq milliequivalents" Ib. pound(s) <br /> 0 ;; g gram(s) i kg kilogram(s) <br /> 'ug microgram(s) ; mg milligram(s) <br /> ml milliliter(s) I liter(s) <br /> m3 cubic meter(s) '! ul microliter(s) <br /> s 3 < less than-The number following the sign is the limit of quantitation,the smallest amount of analyte which can be i <br /> reliably determined using this specific test. a <br /> F <br /> > greater than I <br /> k ; J estimated value—The result is>the Method Detection Limit(MDL)and <the Limit of Quantitation (LOQ), <br /> I <br /> ppm parts per million-One ppm is equivalent to one milligram per kilogram(mg/kg), or one gram per million grams. For <br /> aqueous liquids,ppm is usually taken to be equivalent to milligrams per liter(mg/1), because one liter of water has a <br /> weight very close to a kilogram. For gases or vapors,one ppm is equivalent to one microliter of gas per liter of gas. <br /> ,ppb parts per billion <br /> d i <br /> Dry weight Results printed funder this heading have been adjusted for moisture content. This increases the analyte weight <br /> basis concentration to approximate the value present in a similar sample without moisture. All other results are reported <br /> i on an as-received basis. <br /> I U.S. EPA CLP Data Qualifiers: <br /> Organic Qualifiers Inorganic Qualifiersj1 !I <br /> .A TIC is a possible aldol-condensation product B Value is<CRDL, but>101- <br /> I �13 Analyte was also detected in the blank E Estimated due to interference i <br /> C Pesticide result]confirmed by GC/MS M Duplicate injection precision not met j <br /> fAD Compound quantitated on a diluted sample N Spike sample not within control limits <br /> E Concentration exceeds the calibration range of S Method of standard additions(MSA)used 1 <br /> the instrument for calculation <br /> N Presumptive evidence of a compound(TICS only) U Compound was not detected <br /> € s P Concentration difference between primary and W Post digestion spike out of control limits 1 <br /> 1 confirmation columns>25% Duplicate analysis not within control limits <br /> I ''U Compound was:not detected t Correlation coefficient for MSA<0.995 <br /> X,Y,Z Defined in casenarrative <br /> Analytical test results for methods listed on the laboratories' accreditation scope meet all requirements of NELAC unless <br /> I otherwise noted under the individual analysis. <br /> Measurement uncertainty values, as applicable, are available upon request. <br /> Tests results relate only to the sample tested. Clients should be aware that a critical step in a chemical or microbiological <br /> analysisis.the collection of the sample. unless the sample analyzed is truly representative of the bulk of material involved,the <br /> j test results will be meaningless.; If you have questions regarding the proper techniques of collecting samples, please contact <br /> us. We cannot be held responsible for sample integrity, however, unless sampling has been performed by a member of our <br /> staff. This report shall not be reproduced except in full,without the written approval of the laboratory. <br /> WARRANTY AND LIMITS OF LIABILITY-In accepting analytical work,we warrant the accuracy of test results for the sample as submitted. <br /> THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND 1S GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR <br /> IMPLIED. WE DISCLAIM ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING A WARRANTY OF FITNESS FOR <br /> PARTICULAR PURPOSE AND WARRANTY OF MERCHANTABILITY. IN NO EVENT SHALL LANCASTER LABORATORIES BE LIABLE <br /> FOR INDIRECT,SPECIAL,CONSEQUENTIAL,OR INCIDENTAL DAMAGES INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS <br /> OF PROFIT OR GOODWILL REGARDLESS OF(A)THE NEGLIGENCE(EITHER SOLE OR CONCURRENT)OF LANCASTER <br /> w LABORATORIES AND(B)WHETHER LANCASTER LABORATORIES HAS BEEN INFORMED OF THE POSSIBILITY OF SUCH <br /> DAMAGES. We accept no legal responsibility for the purposes for which the client uses the test results. No purchase order or other order <br /> for work shall be accepted by Lancaster Laboratories which includes any conditions that vary from the Standard Terms and Conditions of 1 <br /> Lancaster Laboratories and we herby object to any conflicting terms contained in any acceptance or order submitted by client. 1 <br /> 3768.02 i <br /> s fl E <br /> I I <br /> i <br /> 4 <br />