Laserfiche WebLink
i <br /> Lancaster Laboratories <br /> 2425New Holland P&L a ancaster,PA 17601 Explanation of Symbols and Abbreviations <br /> The following defines common symbols and abbreviations used in reporting technical data: <br /> N.D, none detected BMQL Below Minimum Quantitation Level <br /> TNTC Too Numerous To Count MPN Most Probable Number <br /> IU International Units CP Units cobalt-chloroplatinate units <br /> umhoslcm micromhoslcm NTU nephelometric turbidity units <br /> C degrees Celsius F degrees Fahrenheit , <br /> meq milliequivalents Ib. pound(s) i <br /> g gram(s) kg kilogram(s) 1 <br /> 'ug microgram(s) mg milligram(s) <br /> ml milliliter(s) I liter(s) <br /> C <br /> 173 cubic meter(s) ul microliter(s) <br /> c less than-The number following the sign is the limit of Quantitation,the smallest amount of analyte which can be <br /> reliably determined using this specific test. <br /> i <br /> r greater than ; <br /> J estimated value—The result is?the Method Detection Limit(MDL)and <the Limit of Quantitation (LOQ). ' <br /> ppmn parts per million-One ppm is equivalent to one milligram per kilogram(mg/kg), or one gram per million grams. For <br /> aqueous liquids,ppm is usually taken to be equivalent to milligrams per liter(mg/1), because one liter of water has a j <br /> weight very close to a kilogram. For gases or vapors,one ppm is equivalent to one microliter of gas per liter of gas. } <br /> ppb parts per billion <br /> Dry weight Results printed under this heading have been adjusted for moisture content. This increases the analyte weight <br /> basis concentration to approximate the value present in a similar sample without moisture. All other results are reported <br /> ` on an as-received basis. <br /> U.S. EPA CLP Data Qualifiers: <br /> Organic Qualifiers Inorganic Qualifiers { <br /> ;A TIC is a possible aldol-condensation product B Value is <CRDL, but>_IDL <br /> ..B Analyte was also detected in the blank E Estimated due to interference a <br /> C Pesticide result confirmed by GC/MS M Duplicate injection precision not met <br /> D Compound quantitated on a diluted sample N Spike sample not within control limits <br /> E Concentration exceeds the calibration range of S Method of standard additions(MSA)used <br /> m. the instrument for calculation , <br /> 'N Presumptive evidence of a compound (TLCs only) U Compound was not detected <br /> P Concentration difference between primary and W Post digestion spike out of control limits <br /> confirmation columns X25% Duplicate analysis not within control limits <br /> U Compound was not detected + Correlation coefficient for MSA<0.995 <br /> X,Y,Z Defined in case narrative <br /> L' Analytical test results for methods listed on the laboratories' accreditation scope meet all requirements of NELAC unless <br /> otherwise noted under the individual analysis. <br /> Measurement uncertainty values, as applicable, are available upon request. <br /> Tests results relate only to the sample tested. Clients should be aware that a critical step in a chemical or microbiological <br /> analysis is the collection of the sample. Unless the sample analyzed is truly representative of the bulk of material involved,the <br /> test results will be meaningless. If you have questions regarding the proper techniques of collecting samples, please contact <br /> us. We,cannot be held responsible for sample integrity, however, unless sampling has been performed by a member of our <br /> staff. This report shall not be reproduced except in full, without the written approval of the laboratory. t <br /> WARRANTY AND LIMITS OF LIABILITY-In accepting analytical work,we warrant the accuracy of test results for the sample as submitted. <br /> LTHE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR <br /> _ IMPLIED. WE DISCLAIM ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING A WARRANTY OF FITNESS FOR <br /> PARTICULAR PURPOSE AND WARRANTY OF MERCHANTABILITY. IN NO EVENT SHALL LANCASTER LABORATORIES BE LIABLE <br /> FOR INDIRECT,SPECIAL,CONSEQUENTIAL,OR INCIDENTAL DAMAGES INCLUDING,BUT NOT LIMITED TO, DAMAGES FOR LOSS <br /> t OF PROFIT OR GOODWILL REGARDLESS OF(A)THE NEGLIGENCE(EITHER SOLE OR CONCURRENT)OF LANCASTER ! <br /> LABORATORIES AND(B)WHETHER LANCASTER LABORATORIES HAS BEEN INFORMED OF THE POSSIBILITY OF SUCH j <br /> DAMAGES. We accept no legal responsibility for the purposes for which the client uses the test results. No purchase order or other order <br /> for work shall be accepted by Lancaster Laboratories which includes any conditions that vary from the Standard Terms and Conditions of <br /> Lancaster Laboratories and we hereby object to any conflicting terms contained in any acceptance or order submitted by client. <br /> ., li 3788.02 <br /> I1 <br /> Li <br /> a l <br />