Laserfiche WebLink
' Table 3 <br /> Slug Test Results <br /> Chevron Station 9-1452 <br /> i 334 Bast Main Street <br /> Ripon, California <br /> 1: <br /> Well Test Slug Transmissivity Conductivity Test Interval <br /> Number Date 'Type' Tye (gpd/ft) (ft/day) Thickness(ft) <br /> = <br /> 1 MW-2 1111101 Slug Insertion PVC Pipe -- -- __ <br /> Slug Removal - -- <br /> 3 <br /> MW-3 1111101 Slug Insertion PVC Pipe 209.83 26.46 6.4$ <br /> Slug Removal emoval 173.83 21.92 6.48 <br /> MW-4 1111101 Slug Insertion PVC Pipe 176.90 .., 27.30 7.93 <br /> Slug Removal 116.58 17.99 7.93 <br /> 1. T <br /> Geometric Mean � 169.29 �22.65 <br />{ * Slug test data were analyzed by Bouwer and Rice(19 76) <br /> --=Responses from slug tests conducted in MW-2 were extremely rapid. Because of this, field data could not <br /> be collected at intervals small enough to illustrate groundwater displacement and recovery from the slug <br /> test, as such,field data collected from these slug tests were not analyzed. <br /> i <br />; <br /> l <br /> i <br /> i <br /> w <br />