Laserfiche WebLink
SYSTEM MONITORING SUMMARY <br /> EVAX TECHNOLOGIES, INC. <br /> Site. Beacon Station J1492 Combustor Start Up: 10/13/89 <br /> 470 North Main Street <br /> Manteca, California <br /> System Combustor Combustor Combustor <br /> Phase Final Test Source Test Source Test <br /> Test Date 11/17/89 11/8/89 10/13/89 <br /> EXTRACTION TVH VP TVH VP TVH VP <br /> POINT <br /> VW-4 875 0 5,500 0 26,600 0 <br /> VW-6 145 C 425 C 7,250 0 <br /> VW-7 795 0 1,580 0 8,600 0 <br /> VW-5 2,550 0 6,900 0 12,425 0 <br /> MW-1 725 0 1 ,230 0 11,850 0 <br /> Detection _-_ -__ <br /> Limit (ppm) 1 0 1 .0 1 .0 <br /> Method TLV TLV TLV <br /> Hours of Operation 24 24 24 <br /> Vacuum ("Hg) 2.0 2 0 ND <br /> Flowrate (scfm) 69 65 22.5 <br /> Influent TVH (ppm) 1,970 4,050 23, 150 <br /> Detection Limit --- ___ _ <br /> Method TLV m 50 50 50 <br /> TLV TLV <br /> EXTRACTION POINT - Extraction probe/well identification as indicated on <br /> site plan. <br /> TVH - Total volatile hydrocarbons in parts per million (ppm) on a <br /> volume/volume basis. <br /> TLV - Threshold Limit Values meter detects combustible gases by <br /> oxidation using a hexane standard. <br /> VP - Manifold valve position. (O=Open) (C=Closed) <br /> Vacuum - System vacuum in inches of Mercury. <br /> scfm - Standard cubic feet per minute. <br /> ND - Not detected. <br />