My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE HISTORY
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1204
>
3500 - Local Oversight Program
>
PR0545490
>
SITE HISTORY
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2020 1:19:43 AM
Creation date
3/10/2020 11:51:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE HISTORY
RECORD_ID
PR0545490
PE
3528
FACILITY_ID
FA0004660
FACILITY_NAME
ACME SAW & INDUSTRIAL SUPPLY
STREET_NUMBER
1204
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
15120616
CURRENT_STATUS
02
SITE_LOCATION
1204 E MAIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN (7' INTY PUBLIC HEALTH SERVICES/ENVIRONMENTAL HEAT"1 DIVISION DATE( <br /> I, ST b'CRKSHEET FCR SITE CLOSURE EVALUATION i <br /> NAME OF FACILITY Iac Al e 1SWE=PS COOP-1 © 5 <br /> ADDRESS (TANK ID 4I •�a G -- <br /> TANK SIzEI ;`,Ora 9FUEL TYPE( G AS /�� ,2 s_v <br /> b �c <br /> It. GENERAL SITE HISZdRY, <br /> *** <br /> Is permit current?IYes No Permit N% - Facility Status Codel 00c.Soil/GW Cont Yes INoI <br /> (Number of Tanks at facility )Age of Tanks(if available) Type of Tank steel IFbrgl Sngll Oual <br /> III. TANK HISTORY <br /> Was Tank tested? Yes INo xiFailed precision test ?IYesI No lif yes, give date(s)l <br /> Was a repair made to the tank sys-.em?j`Yes7 No If yes, what was repaired? <br /> Was repair done under inspection) Yesl Nol Were soil samples analyzed? Yes) INoI BTXEI ITPH-GI ITPH-01 Pb/EDB <br /> Type of failure/discharge% catastrophic hong-term Leakage Ioverfill Iunknown I other: <br /> IV. REMOVAL HISTORY (ATTACH INSPECTION REPORT FOR SITE OETAILS/COLLECT DATA FOR LEACHING POTENTIAL ANALYSIS) <br /> Soil Samples Received Yes Hol (Depth to Ground Water �IRef/Yearl ; Average Annual PrecipitationlA= 14 10-25 <br /> On-Site Well(s)IYes I INoI (Number & Type Iirr (Dam) IPubI <br /> S Score S Score S Score <br /> (Distance to Wells) from Tankl ft; ft; ft C 10 pts C 9 pts C 5 pts <br /> 0 if 0 if 0 if <br /> R condition R condition R condition <br /> V. Site Feature - Leaching Potential Analysis E is met E is met E is met <br /> )Minimum Depth to groundwater from the Soil Sample (feet) C I >100 I I51-100 125-10\1 <br /> (Fractures in subsurface (applies to foothills or mountain areas) + �i Hone I I Unknown I (Present <br /> lAverage ,annual Precipitation (inches) xxxxxxl <10 I 9 1 10-25 Ixxxxxxxl 26-40\2 <br /> (Man-Made conduits which increase vertical migration �o I I I I jPresent <br /> of leachate (i.e., septic system;, water wells, ponds) S1 �� None Unknown <br /> Unique site features: Recharge area, coarse soil, nearby wells. At leastMore than <br /> xxxxxx None I ( one) one <br /> COLUMN TOTALS>»TOTAL POINTS ' I + I (� I + 1 10 1.3 g <br /> Sample Result: (3 T X OR :) RANGE OF TOTAL POINTS 49 pts or more I 41 - 4a pts ( 40 pts or Less <br /> D 31T1X1 - 1 'B J.TIX1MAXIMUMALLOWABLE 3-T-X-E LEVELS (PPM) 1 50 S0 50 33 i 1. NA\3 <br /> Sample Result: H7GAWLIHE 1000 100 I 10 <br /> } D MAXIMUM ALLOWABLE TPN LEVELS (PPM) <br /> N <br /> 'PH 10,000 % 1000 l� 100 <br /> FOOTNOTES: "*if documented soil and/or ground water contamination is present, do not complete the leachmn ential <br /> analysis. (i.e., site is currently on UGT Contamination List for soil or ground water.) <br /> \1 If depth is > 5 ft. and < 25 ft., score 0 points. If depth �=5 ft., do not use table. <br /> \2 If precipitation is > 40 inches, score 0 points. <br /> \3 Levels for 3TX&E are not applicable at a TPH concentration of 10 ppm <br /> _� �(gasoline) or 100 ppm (diesel). <br /> VI. STAFF RECOMMENDATION/CONCLUSION! —r&! 2 <br /> 1. Are 3TX & E or TPH Concentrations r Allowable Levels I*Yes INo+ I P ie-c-e s,. <br /> 2. 2eco mmend Site Closure IYesl INoI II f Yes, Refer to Site Mitigation for 'Evaluation <br /> VII. REVIEW EVALUATION - TO 3E a PLETED 3Y A SUPERVISCR/SENIOR <br /> CONCUR 'JITH STAFF RECO"ENDATICN FOR CLOSUREIYESI INOI IREFERRED TO SITE MITIGATION FOR cVALUATICNIYESI INOI <br /> i <br /> DATE REFERRED( (DATE CLOSURE LETTER MAIL..DI <br /> NAME OF <br /> EVALUATORI <br /> EH 23 80 (UGTWKSHT)\5/90 <br />
The URL can be used to link to this page
Your browser does not support the video tag.