Laserfiche WebLink
TABLE 2 <br /> (MW-2 - CONCENTRATIONS IN SOIL PPM <br /> SAMPLE TPHG TPHD MTBE B T E X <br /> B2-5 NA NA NA NA NA NA NA <br /> B2-10 NA NA NA NA NA NA NA <br /> B2-15 NA NA NA NA NA NA NA <br /> B2-20 NA NA NA NA NA' NA NA <br /> B2-25 NA NA NA NA NA NA NA <br /> B2-30 ND ND ND ND ND ND ND <br /> B2-35 1 . 5 ND ND 0.21 0. 049 0. 009 0 . 13 <br /> B2-40 1 . 2 ND ND 0 .079 0 .034 ND 0 .017 <br /> B2-45 1 . 6 ND . 0075 0. 33 0 . 078 0 . 043 0 . 082. <br /> B2-50 4. 3 ND ND 0. 14 0. 20 0 . 053 0 .21 <br /> B2-55 ,< 7 ND 0 .012 0 .029 0. 81 0 . 17 0.75 <br /> B2-60 4.7 ND 0 . 025 �'0� 73' 0. 69 0 . 15 . 0. 75 <br /> B2-65 3 . 8 ND 0 . 053 0 . 63 0 .035 0.030 0 . 16 <br /> B2-70 1 . 5 ND 0.0056 0. 70 0. 023 ND 0 . 11 <br /> :. N 2.""'�. 0.033 ND 0.088 <br /> NA = NOT APPLICABLE <br /> ND = NOT DETECTED <br /> The soil samples taken from the MW-2 boring from 30 feet below <br /> grade to the termination of drilling contained TPHG, MTBE and <br /> BTEX at concentrations which were above Non-Detectable. <br /> The PID readings were essentially background for the first SIX <br /> samples collected in the soil borings for MW-2. <br /> 7 <br />