Laserfiche WebLink
MONITORING WELL <br /> CONSTRUCTION <br /> I DETAILS <br /> PROJECT NO: 19012.04 MONITORING WELL NO.: MW-1 <br /> LOCATION: Beacon #474 <br /> 3440 East Main Street ELEVATION: 100.00 feet <br /> Stockton, California <br /> Protective Casing <br /> JI- <br /> 9 Locking Water Tight Gap <br /> Flush Grade Well Construction <br /> Diameter and Mat'I 12—inch steel <br /> Total length 12 inches <br /> Length Above Ground 1/4 inch <br /> Thickness and Type of Seal 2 feet, concrete <br /> Diameter, Mat'I and 4 inch, SCH 40 PVC <br /> Joint Type of Riser Pipe flush thread <br /> cv <br /> J <br /> Type of Backfill cement/ g% <br /> Around Riser <br /> bentonite grout <br /> Thickness and Type 2 feet <br /> -j of Seal bentonite chips <br /> Distance of Filter Sand <br /> Above Top of Screen 2 feet <br /> Type of Filter #3 lonestor <br /> Around Screen <br /> Monitoring Well Mat'I SCH 40 PVC <br /> Screen Gauge/Slot Size 0.020 inch <br /> J <br /> Diameter and Length 4 inch, 15 feet <br /> of Screen <br /> Depth to Bottom <br /> of Monitoring Well 90 feet <br /> Depth to the Bottom <br /> of Filter Sand 90 feet <br /> 10 in --] <br /> MONITORING WELL WATER LEVEL MEASUREMENTS <br /> L1 = 0.25 feet <br /> L2 = 74.75 feet Date: Time: Water Level* <br /> L3 = 15.00 feet 12/14/93 8:24 prn 80.24 ft, <br /> L4 = 90.00 feet <br /> Completion Date and Time: 12/14/93 8:24 pm * Measuring Point: Top Of Casing <br /> ACTON • MICKELSON VAN DAM, INC. <br /> 5090 Robert J. Mathews Parkway #4 <br /> EI Dorado Hills, CA 95762 <br />