ConocoPhillips 2705445 SECOR <br /> January 15, 2007 <br /> Page 3 <br /> Laboratory analytical data for groundwater samples collected during this investigation indicate the <br /> following: <br /> • The highest concentrations of GRO (6,000 ug/L)and BTEX (150 ug/L, 970 ug/L, <br /> 200 ug/L and 1,000 ug/L)were reported for the B-7 groundwater sample. <br /> The highest concentrations of MTBE and TBA were detected in the groundwater <br /> sample collected from B-11 at 60,000 ug/L and 7,700 ug/L, respectively. <br /> QA/QC <br /> Method blank for DRO analysis on samples B-7@55'contained a target compounds above <br /> the reporting limit. The sample contained greater than 10X the value found in the method <br /> blank; therefore, re-extraction and or re-analysis of the sample was not performed. <br /> Method blanks for DRO analysis on samples B-9@50', B-8@50', B-10@35,' B-1 0@50', B- <br /> 7@20',and B-1 @55', contained a target compounds above the reporting limit. None of the <br /> samples associated with the method blank contained the target compound; therefore, re- <br /> extraction and or re-analysis of the sample was not performed. <br /> Surrogate recoveries were not reported for sample B-7@20' due to required dilution. <br /> Waste Removal <br /> Soil cuttings and decontamination rinsate water generated during the site assessment activities <br /> were stored in Department of Transportation (DOT)approved 55-gallon capacity steel drums. The <br /> drums were staged onsite pending laboratory characterization as non-hazardous waste. Filter <br /> Recycling Services (FRS) of Colton, California transported the drums to their licensed facility in <br /> Rialto, California for disposal on February 3,2007. Waste disposal details will be submitted under a <br /> separate cover on a later date. <br /> Limitations <br /> This site assessment report has been prepared for the exclusive use of ConocoPhillips and its <br /> representatives as it pertains to the property located at 1206 E. March Lane, Stockton, California. <br /> Evaluations of the geologic conditions at the site for the purposes of this investigation are inherently <br /> limited due to the number of observation points. There are no representations, warranties, or <br /> guarantees that the points selected for sampling are representative of the entire site. Data from this <br /> report reflects the conditions at specific locations at a specific point in time. No other interpretation, <br /> representations,warranties, guarantees, express or implied, are included or intended in the report <br /> findings. SECOR assumes no responsibility for exploratory borings or data provided or reported by <br /> other consultants or contractors. <br /> hConocoPhillips\Due Diligence\2705445\report\2705445 Due Diligence report.doc <br />