Laserfiche WebLink
KLEINFELDER <br /> B-6 LEACHATE MONITORING <br /> r 1. The leachate riser or wells are first opened and allowed to equilibrate with the <br /> 4• atmosphere. <br /> 2. The leachate elevation is then measured from a set location using a conductivity-based <br /> water-level meter. The level is generally measured from a surveyed mark on the north <br /> rim of the casing. <br /> r 3. A leachate sample is then collected using a clean, disposable bailer. <br /> L <br /> 4. The sample is labeled and immediately stored in an iced cooler pending transport to the <br /> analytical laboratory. The sample is togged on a chain-of-custody. <br /> B-7 SURFACE WATER MONITORING <br /> 1. Prior.to collecting surface water samples, the depth of water is estimated at a designated <br /> location in the surface water body. <br /> 2. Surface water samples are collected directly from the stream or surface water using a <br /> clean unpreserved plastic bottle, disposable bailer, bailer, coliwasa, DipstikTM, dipper, <br /> peristaltic pump, etc., or by directly filling the sample containers. .Sampling equipment <br /> will either be disposable, dedicated or decontaminated in accordance with the above- <br /> defined decontamination protocols. Care is taken not to disturb the stream bottom and <br /> introduce sediment in the sample. The fluid is then poured into appropriate preserved or <br /> unpreserved bottles for the requested analysis. <br /> 3. The sample is labeled and immediate) stored in an iced cooler pending transport to the <br /> Y P g P <br /> analytical laboratory. The sample is logged on a chain-of-custody. <br /> B-8 TANK REMOVAL SAMPLING <br /> B-8.1 Collection of Soil Samples and Laboratory Analysis <br /> Soil and water samples will be collected during the tank removal operations in accordance with <br /> the current Leaking Underground Fuel Tank Field (LUFT) Manual and the Tri-Regional <br /> Guidelines issued by the California Regional Water Quality Control Board (RWQCB). <br /> r 34202.E01 /ST03R1130 <br /> Page 8 of 9 <br /> Copyright 2003,Kleinfelder,Inc. August 8,2003 <br />