Laserfiche WebLink
' notes during the investigative work , and Exhibit G contains <br /> copies of the lab results. <br /> On November 19, 19911 Geological Audit Services, Inc. submitted a <br /> workplan to the County EHD for excavation & removal of the <br /> ' contaminated soil from the site; (refer to Exhibit F.) That <br /> workplan was not implemented, and no work has been done on the <br /> site since October of 1991 . <br /> tIn June, 1992, Wm. J. Hunter & Associates were retained oy Husky <br /> Crane to review & analyze the prior work, and prepare a workplan <br /> for delineating the vertical & lateral extent of the contamina- <br /> tion encountered during the work in October , 1991. The site of <br /> the removed UST 's is immediately adjacent to the Husky Crane--BUJ <br /> Co. property line as shown on Plate VI. As mentioned earlier , an <br /> ' observation well has recently been placed on BJJ property to <br /> monitor possible groundwater- contamination caOsed by a 3500 <br /> gallon fuel tank which is located beneath a building and could <br /> not be removed. Soil borings beneath that tank showed <br /> ' <br /> significant levels of contaminants, and a water sample tar en from <br /> the monitoring well an December 1991 revealed S5 ppb gasoline. <br /> Besides the existing UST, there were two �2) above-ground <br /> gasoline tanks on the BJJ site about 5G feet northeasterly from <br /> the location of the removed tanks on the HusKy Crane property. <br /> ' Those tanks were recently remo-,ed ana replaced with UST s in the <br /> same location. Details of that work have not been reviewed. <br /> During investigative work conducted last year at Husky Crane, <br /> ' contamination was noted on the wall of the excavation abatting <br /> BJJ Co. Surface drainage as shown on the € SGS topographic sheet, <br /> (Plate II,) is generally west/southwest , from BJJ towards <br /> ' Husky Crane. Based on limited data, the groundwater gradient <br /> as towards the east, away from Husky Crane. <br /> ' Although contamination was encountered during investigative work <br /> at Husky Crane at S " bgl immediately adjacent to the BJJ Co. <br /> property, the source of that contamination has not vet been <br /> determineo. Until more information has been obtained , our client <br /> ' does not wish Lo conduct investigative work offsite at this time. <br /> Therefore, the following workplan is restricted to the Husky <br /> Crane property only. <br /> ' WORKPLAN FOR SOIL INVESTIGATION <br /> 1 . Move in properly licensed auger-drilling rig equipped with <br /> clean 7 1t4" OD flights & soil sampling equipment. <br /> 4 <br />