Laserfiche WebLink
EXCELCHEM <br /> ENVIRONMENTAL LABS <br /> 500 Giuseppe Court, Suite 9 <br /> Roseville, CA 95678 <br /> Phone# (916) 773-3664 Fax#- (916) 773-4784 <br /> ANALYSIS REPORT <br /> Attention Mr Matthew Taylor Date Sampled 08-16-96 <br /> Wallace-Kuhl & Associates Date Received 08-19-96 <br /> 3050 Industrial Blvd Date Analyzed 08-21-96 <br /> West Sacramento, CA 95691 Matrix Water <br /> Project 2938 0311444 Manposa <br /> Ethyl- Total <br /> Benzene Toluene benzene Xylenes TPHg TPHd <br /> PPB PPB PPB PPB PPB PPB <br /> R rtm L11illt 05 05 0 5 0 5 50 50 <br /> SAMPLE <br /> Labalatoly Identification <br /> MW 1 156 2 9 10 3 3 484 ND <br /> • W0896324 <br /> MW2 24 2 2 1 0 8 1 9 313 ND <br /> W0896325 <br /> MW3 ND ND ND ND ND ND <br /> W0896326 <br /> TB ND ND ND ND ND NR <br /> W0896327 <br /> PPB=Parts per billion=uglL=micrograms per liter <br /> IND=Not detected. Compound(s)may be present at concentrations below the reporting limit. <br /> NR=Not requested <br /> ANALYTICAL PROCEDURES <br /> BTF—X— 9enzene, toluene, ethylbowmic and total xylene isomers (BTEX) are analyzed by using EPA Method 602 which utilizes a gas <br /> chromatograph(GC)equipped with a phototonization detector(PID) <br /> TPHg—Total petroleum hydrocarbons as gasoline(low-to-medium boiling points)are analyzed by using modified EPA Method 8015,wtuch utilizes a <br /> GC equipped with an FID <br /> TPHd—Total petroleum hydrocarbons as diesel(high boiling points)are measured by extraction using EPA Method 35 t0 followed by modified EPA <br /> 8015 with direct sample infection into a GC equipped with an FID <br /> 08-26-96 <br /> Lab ratory Representative Date Reported <br />