Laserfiche WebLink
BLINCO TRUCKING Page 1 of 2 <br /> LTCP Checklist GO GEOTRACKER HOME MANAGE PROJECTS I REPORTS I SEARCH I LOGOUT <br /> BLINCO TRUCKING(T10000005922)-MAP THIS SITE OPEN-SITE ASSESSMENT <br /> 2431 EAST MARIPOSA ROAD CLEANUP OVERSIGHT AGENCIES <br /> STOCKTON,CA 95205 ACTIVITIES REPORT SAN JOAQWN COUNTY LOP(LEAD)-CASE A:2118 <br /> CASEWORKER:GABRIEL GONZALEZ-SUPERVISOR:ADRIENNE ELLSAESSER <br /> SAN JOAQUIN COUNTY PUBLICWEBPAGE CENTRAL VALLEY RWQCB(REGION 5S)-CASE A:391195 <br /> VIEW PRINTABLE CASE SUMMARY FOR THIS SITE CASEWORKER:CORI CONDO N-SUPERVISOR:BRIAN NEWMAN <br /> THIS PROJECT WAS LAST MODIFIED BY VICKI MCCARTNEY ON 5/19/2014 9:29:51 AM-HISTORY <br /> CLOSURE POLICY THIS VERSION IS FINAL AS OF 5/19/2014 CHECKLIST INITIATED ON 511912014 CLOSURE POLICY HISTORY <br /> General Criteria-The site satisfies the policy general criteria-CLEAR SECTION ANSWERS NO <br /> a.Is the unauthorized release located within the service area of a public waters stem? <br /> Name of Water system: JPVTCALWATER f' YES r^ NO <br /> b.The unauthorized release consists only of petroleum info G YES C NO <br /> c.The unauthorized("primary")release from the UST system has been stopped. G YES C NO <br /> d.Free product has been removed to the maximum extent practicable info r FP Not Encountered C YES C NO <br /> e.A conceptual site model that assesses the nature,extent,and mobility of the release has been developed info. <br /> Description(Check all that Apply): <br /> (✓ GW Not Evaluated <br /> F Groundwater Assessment Incomplete-Areal Extent of Contamination Not Defined <br /> F Groundwater Assessment Incomplete-Depth of Contamination Not Defined <br /> Fv-Hydrogeology Not Adequately Defined <br /> C YES f' NO <br /> I✓ Potential Receptors Not Identified <br /> P Soil Assessment Incomplete-Areal Extent Not Defined <br /> F Soil Assessment Incomplete-Depth Unknown <br /> R-Soil Vapor Not Evaluated <br /> F Other - <br /> f.S conclaFy source has been removed to the extent practicable info <br /> Impediment to Removing Secondary Source(Check all that Apply): <br /> Remediation Has Not Been Attempted <br /> Remediation Was Designed Incorrectly C YES E' NO <br /> (—Remediation Was Shut Off Prematurely <br /> F Poor Remediation O&M <br /> F Other - I Two USTs removed;new case in site asse <br /> g.Soil or groundwater has been tested for MTBE and results reported in accordance with Health and Safety Code Section <br /> 25296.15 E' Not Required r YES r NO <br /> h.Does a nuisance exist,as defined by Water Code section 13050. C YES r NO <br /> 1.Media-Specific Criteria:Groundwater-The contaminant plume that exceeds water quality objectives is stable or decreasing in areal extent,andNO <br /> meets all of the additional characteristics of one of the five classes of sites listed below.-CLEAR SECTION ANsWERs <br /> EXEMPTION-Soil Only Case(Release has not Affected Groundwater-Info) f YES I' NO <br /> Does the site meet any of the Groundwater specific criteria scenarios? r YES r NO <br /> ADDITIONAL QUESTIONS-Please indicate only those conditions that do not meet the policy criteria: <br /> Plume Length(That Exceeds Water Quality Objectives): <br /> C >_100 Feet and<250 Feet C >250 Feet and<1,000 Feet r >_1,000 Feet E.- Unknown <br /> Plume is Stable or Decreasing in AREAL Extent <br /> C No r Unknown <br /> Free Product in Groundwater: <br /> C Yes C No G Unknown <br /> Free Product Has Been Removed to the Maximum Extent Practicable <br /> C No C Unknown <br /> For sites with free product,the Plume Has Been Stable or Decreasing for 5-Years(info) <br /> C' No r' Unknown <br /> For sites with free product,owner Willing to Accept a Land Use Restriction(if required) <br /> r- No C Unknown <br /> Free Product Extends Offsite <br /> C Yes C Unknown <br /> Benzene Concentration <br /> E >_1.000 Ng/I and<3,000 pg/I E' i 3,000 Ng/I (0- Unknown <br /> MTBE Concentration: <br /> C >_1,000 Ng/I E-- Unknown <br /> Nearest Supply Well(From Plume Boundary) <br /> C s 250 Feet C>250 Feet and s 1,000 Feet E-- Unknown <br /> Nearest Surface Water Body(From Plume Boundary): <br /> C s 250 Feet C- >250 Feet and s 1.000 Feet C Unknown <br /> https:Hgeotracker.waterboards.ca.gov/regulators/screens/closure_policy.asp?global_id=T 1... 5/19/2014 <br />