My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE_CASE 2
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
2431
>
2900 - Site Mitigation Program
>
PR0538868
>
SITE INFORMATION AND CORRESPONDENCE_CASE 2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/12/2020 2:38:50 PM
Creation date
3/12/2020 11:33:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
FileName_PostFix
CASE 2
RECORD_ID
PR0538868
PE
2950
FACILITY_ID
FA0022329
FACILITY_NAME
BLINCO TRUCKING
STREET_NUMBER
2431
Direction
E
STREET_NAME
MARIPOSA
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
17130003
CURRENT_STATUS
01
SITE_LOCATION
2431 E MARIPOSA RD
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BLINCOE TRUCKING 1%� .�. Page 1 of 1 <br /> LTCP Checklist GO GEOTRACKER HOME IMANAGE PROJECTS IREPORTSI SEARCH I LOGOUT <br /> BLINCOE TRUCKING(T10000005922)-MAP THIS SITE OPEN-ELIGIBLE FOR CLOSURE <br /> 2431 EAST MARIPOSA ROAD CLEANUP OVERSIGHTAGENCIES <br /> 2431 EA TMARIPOSA ACTIVITIES REPORT SANJOAQUINCOUNTY LOP(LEAD)-CASE#:2118 <br /> CASEWORKER:GABRIEL GONZALEZ-SUPERVISOR:ADRIENNE ELLSAESSER <br /> SAN JOAQUIN COUNTY PUBLIC WEBPAGE CENTRAL VALLEY RWQCB(REGION 5S)-CASE#:391195 <br /> VIEW PRINTABLE CASE SUMMARY FOR THIS SITE CASEWORKER:CORI CONDON-SUPERVISOR:BRIAN NEWMAN <br /> CUF Claim#:20122 CUF Priority Assigned:C CUF Amount Paid:IQ <br /> CR Site ID#:NOT SPECIFIED <br /> THIS PROJECT WAS LAST MODIFIED BY NUEL HENOERSON ON 3123/2015 3:15:49 PM-HISTORY <br /> THIS SITE HAS SUBMITTALS.CLICK HERE TO OPEN A NEW WINDOW WITH THE SUBMITTAL APPROVAL PAGE FOR THIS SITE. <br /> CLOSURE POLICY THIS VERSION IS FINAL AS OF 3/23/2015 CHECKLIST INfTIATED ON 611WM4 CLOSURE POLICY HISTORY <br /> General Criteria-The site satisfies the policy general criteria-CLEAR SECTION ANSWERS NO <br /> a.Is the unauthorized release located within the service area of a public waters stem? <br /> Name of Water System <br /> PVT CAL WATER YES NO <br /> b.The unauthorized release consists only of petroleum lbl. r YES r NO <br /> C.The unauthorized("primary")release from the UST system has been stopped. r YES r NO <br /> d.Free product has been removed to the maximum extent practicable Lbfaj. (: FP Not Encountered r YES C NO <br /> e.A conceptual site model that assesses the nature,extent,and mobility of the release has been developed liffM. G YES C NO <br /> f.Secondary source has been removed to the extent practicable jbfol. C! YES C NO <br /> g.Soil or groundwater has been tested for MTBE and results reported in accordance with Health and Safety Code Section C Not Required C YES t:' NO <br /> 25296.15. <br /> h.Does a nuisance exist,as defined by Water Code section 13050. C YES r NO <br /> 1.Media-Specific Criteria:Groundwater-The contaminant plume that exceeds water quality objectives is stable or decreasing in areal extent,and YES <br /> meets all of the additional characteristics of one of the five classes of sites listed below.-CLEAR SECTION ANSWERS <br /> EXEMPTION-Soil Only Case(Release has not Affected Groundwater-Info) C YES fJ NO <br /> Does the site meet any of the Groundwater specific criteria scenarios? OF YES C NO <br /> 1.5-The regulatory agency determines,based on an analysis of site speck conditions,that the site undercurrent and reasonably anticipated near-term <br /> future scenarios,the contaminant plume poses a low threat to human health and safety and to the environment and water quality objectives will be achieved F YES C NO <br /> within a reasonable time frame. <br /> 2.Media Specific Criteria:Petroleum Vapor Intrusion to Indoor Air-The site is considered low-threat for the vapor-intrusion-to-air pathway if YES <br /> site-specific conditions satisfy items 2a,2b,or 2c-CLEAR SECTION ANSWERS <br /> EXEMPTION-Active Commercial Petroleum Fueling Facility C YES 0_ NO <br /> Does the site meet any of the Petroleum Vapor Intrusion to Indoor Air specific criteria scenarios? G YES C NO <br /> 2C-Petroleum Vapor Intrusion to Indoor Air-The regulatory agency has determined petroleum vapors migrating from soil or groundwater will have no <br /> significant risk of adversely affecting human health as a result of controlling exposure through the use of mitigation measures or through the use of G YES C NO <br /> institutional or engineering controls. <br /> 3.Media Specific Criteria:Direct Contact and Outdoor Air Exposure-The site is considered low-threat fordirect contact and outdoorair exposure FYES <br /> if it meets 1,2,or 3 below.-CLEAR SECTION ANSWERS <br /> EXEMPTION-The upper 10 feet of soil is free of petroleum contamination C YES r NO <br /> Does the site meet any of the Direct Contact and Outdoor Air Exposure criteria scenarios? OF YES r NO <br /> 3.3-The regulatory agency has determined the concentration of petroleum constituents in soil will have no significant risk or adversely affect human health. r YES r NO <br /> Additional Information <br /> Should this case be closed in spite of NOT meeting policy criteria? C' YES 0' NO <br /> Has this LTCP Checklist been updated for FY 14!15? G' YES C NO <br /> SPELL CHECK <br /> Save Form as Partially Completed Save Form as Complete <br /> LOGGED IN AS GAGONZALEZ CONTACT GEOTRACKER HELP <br /> https://geotracker.waterboards.ca.gov/regulators/screens/closure_policy.asp?global_id=T 10... 4/3/2015 <br />
The URL can be used to link to this page
Your browser does not support the video tag.